background image

User’s Manual 

CD3000S-3PH from 125A to 500A 

Honeywell

 

5.4 LED Status Table 

 

LED STATUS 

DESCRIPTION 

PW 

(green led) 

 

Auxiliary supply is not connect 

 

 

Auxiliary supply is connect 

ON 

(green led) 

 

OFF Condition (Load IS NOT Powered) 

 

 

ON Condition (Load IS Powered) 

 

 

  = Light OFF 

  = Light ON 

 17 

www.honeywell.com/imc

 

Содержание CD3000S-3PH

Страница 1: ...EN1I 6305 USER S MANUAL CD3000S 3PH THYRISTOR UNIT From 125A to 500A Rev 12 2004 ...

Страница 2: ...EN1I 6305 ...

Страница 3: ...nstallation and wiring information 8 4 1 Identification of the unit 8 4 2 Installation 8 4 3 Dimensions 9 4 4 Fixing Holes 10 5 Wiring instructions 11 5 1 Removing the cover 11 5 2 Cabling detail 14 5 3 Wiring connection 16 5 4 LED Status Table 17 6 Start up 18 6 1 Auxiliary supply 19 6 2 Input configuration 20 7 Thyristor firing mode 21 7 1 Zero Crossing ZC 21 8 Fuses and fuseholder 22 8 1 Fuses ...

Страница 4: ...ristor unit is only permitted to specialized personnel the authorised personnel must read this manual before to have access to the unit the access to the units must be denied to unauthorized personnel Important warnings attention Local regulations regarding electrical installation should be rigidly observed Safety regulations must be rigidly observed Don t bend components to maintain insulation di...

Страница 5: ...e supply for all electronic circuit but not in parallel with contactor s coil solenoids and other inductive or capacitive loads It s recommended to use a shielded transformer Electromagnetic compatibility compatibilité électromagnétique Our thyristor unit has an excellent immunity to electromagnetic interferences if all suggestions contained in this manual are respected In respect to a good Engine...

Страница 6: ...mand from controller the error signal is used to automatically hold the power at demanded level 1 4 What is a thyristor unit A thyristor unit is semiconductor device which acts as a switch formed by two thyristors in antiparallel To switch on the alternating current the input signal will be on and the thyristor will switch off at first zero crossing voltage with no input signal The benefits of thy...

Страница 7: ... request Input signal SSR Firing mode Zero Crossing ZC Auxiliary voltage supply 230 Æ 200 230V 15 10 VA power consumption 460 Æ 300 460V 15 10 VA power consumption Fan voltage supply 230V 15 110V 15 on request Fuses Internal Mounting Bulk head mounting Protection IP20 2 2 Input features Input signal Maximum current drain Input Impedance ON condition OFF condition SSR 5mA constant current 4V max 30...

Страница 8: ... 1200 1600 200 7800 15 300000 47 70 1260 2500 400 24 600 1200 1600 200 8000 15 306000 47 70 1440 2500 450 24 600 1200 1600 1000 17800 15 1027000 47 70 1620 2500 500 24 600 1200 1600 1000 17800 15 1027000 47 70 1800 2500 2 4 Derating curve 1 0 8 0 6 0 4 0 2 0 45 55 65 75 85 K C I I x K NOM MAX 2 5 Fans The thyristor units are equiped with a fan The fan supply must be protected with a fuse Fan volta...

Страница 9: ...oltage supply Specify the value of the line supply 3 Max VOLTAGE of CD3000S 480V 600V The voltage on the identification label must be equal or more than operating voltage The minimum voltage supply to the load is 24V 4 Auxiliary Voltage 230V 200 230V 15 10VA 460V 300 460V 15 10VA 600V 600V 15 10VA on request 5 Input SSR 4 30VDC 6 Firing ZC Zero Crossing 7 Options FAN110 Fan voltage supply 110VAC 1...

Страница 10: ...ding the factory settings of the unit This label is on the board inside the unit as represented below 4 2 Installation Identification Label CD3000S unit should be always mounted in vertical position to improve air cooling on heatsink Maintain minimum distances in vertical and in horizontal as below represented Don t install in proximity of hot elements and near units generating electromagnetic int...

Страница 11: ...500A Honeywell 4 3 Dimensions Size W mm H mm D mm 125A S11 137 440 270 150A S11 137 440 270 225A S13 262 440 270 300A S14 262 520 270 350A S14 262 520 270 400A S14 262 520 270 450A S14 262 520 270 500A S14 262 520 270 9 www honeywell com imc ...

Страница 12: ...er s Manual 4 4 Fixing Holes A B C Size A mm B mm C mm 125A S11 97 415 97 150A S11 97 415 97 225A S13 222 415 222 300A S14 222 495 222 350A S14 222 495 222 400A S14 222 495 222 450A S14 222 495 222 500A S14 222 495 222 www honeywell com imc 10 ...

Страница 13: ...ted heatsink For safety connect the heatsink to hearth using its terminal with hearth symbol CD3000S can be susceptible to airborne interferences from near equipment or from interferences on main supply so a number of precautions must be taken Contactors coils and chokes must have in parallel a RC filter and must be supplied with a different voltage line All input output signal must use screened b...

Страница 14: ...t 2 N C not connected 3 Auxiliary supply voltage 230 460Vac 600V opt 4 N C not connected 5 Fan supply 230V 110V opt 6 Fan supply 230V 110V opt 7 Reset 8 Reset 9 Input command signal SSR 10 Input command signal SSR 11 Volt GND 12 Output 8Vdc stabilized 1mA max 13 Output command signal to CD3000 slave 14 Output command signal to CD3000 slave 15 Not used 16 Not used 17 Not used 18 Not used 19 Not use...

Страница 15: ...ires are insulated from the voltage Terminal Description L1 Line Input Phase 1 T1 Load Output Phase 1 L2 Line Input Phase 2 T2 Load Output Phase 2 L3 Line Input Phase 3 T3 Load Output Phase 3 S11 power connection S13 power connection S14 power connection T1 T2 T3 L1 L2 L3 T1 T2 T3 L3 L1 L2 L1 T1 L2 T2 L3 T3 L1 L2 L3 T1 T2 T3 13 www honeywell com imc ...

Страница 16: ... provided with the terminal type indicated below Current courant Torque couple Lb in N m Wire Range cable Wire Terminal terminal 125A 150A 225A 310 35 0 Polymeric Terminal Block M8 300A 372 42 0 Bus Bar Adapter M8 350A 400A 18 600kcmil 450A 500A 505 57 0 Bus Bar Bus Bar Adapter M10 www honeywell com imc 14 ...

Страница 17: ...0 2 x 1 0 M8 350A 2 x 95 2 x 3 0 M10 2 x 95 2 x 3 0 M10 400A 2 x 95 2 x 3 0 M10 2 x 95 2 x 3 0 M10 450A Bus Bar 30 x 6 mm Bus Bar 30 x 6 mm 500A Bus Bar 60 x 4 mm Bus Bar 60 x 4 mm Auxiliary connectors and earth Current Auxiliary Supply Earth Cable Cable mm2 AWG mm2 AWG Screw M 125A 0 50 18 16 6 M6 150A 0 50 18 16 6 M6 225A 0 50 18 25 4 M8 300A 0 50 18 50 1 M8 350A 0 50 18 50 1 M8 400A 0 50 18 50 ...

Страница 18: ... 240 460V 1 2 19 20 FAN SUPPLY 230V Std INPUT SIGNAL SSR Volt mA NOTE IMPORTANT The user installation must be protected by electromagnetic circuit breaker or by fuse isalator If the auxiliary voltage written on the identification label is different from supply voltage to the load use an external transformer as reported above To work terminals 7 8 must be linked Fan voltage supply is standard 230VA...

Страница 19: ...Honeywell 5 4 LED Status Table LED STATUS DESCRIPTION PW green led Auxiliary supply is not connect Auxiliary supply is connect ON green led OFF Condition Load IS NOT Powered ON Condition Load IS Powered Light OFF Light ON 17 www honeywell com imc ...

Страница 20: ... than nominal verify that all auxiliary connections are right fan voltage equal than nominal 230V std 110V optional After which supply thyristor unit giving the maximum input signal and verify that load current is equal or less than thyristor unit nominal current Warning this procedure can be done just by specialized personnel The thyristor unit is delivered configured and tuned in line with custo...

Страница 21: ... jumpers for S11 S13 and S14 sizes J11 J10 J9 230V Auxiliary supply To set the auxiliary power supply to 230V close J9 and J11 and open J10 as shown below 460V Auxiliary supply To set the auxiliary power supply to 460V close J10 and open J9 and J11 as shown below 600V Auxiliary supply This is a special version on request In this case the unit is supplied already configured J11 J10 J9 J11 J10 J9 J1...

Страница 22: ... 2 Input configuration Warning this procedure can be done just by specialized personnel Location of auxiliary supply jumpers for S11 S13 and S14 sizes Jumpers Configuration MAIN PCB Input J7 J16 J17 J13 SSR A B C A B C A B C FITTED www honeywell com imc 20 ...

Страница 23: ...E SUPPLY V ZERO CROSSING 7 1 Zero Crossing ZC ZC firing mode is used with Logic Output from temperature controllers and the Thyristor operate like a contactor The Cycle time is performed by temperature controller ZC minimize interferences because the Thyristor unit switch ON OFF at zero voltage 21 www honeywell com imc ...

Страница 24: ... 125A 2x 100 FE 100 2800 660 2 x 6 9 URY 17 100 100 3900 690 150A 2x 100 FE 100 2800 660 2 x 6 9 URY 17 100 100 3900 690 300A 450 FMM 450 105000 660 6 6 URZ 2X000 BS88 Z 450 450 126000 660 350A 550 FMM 550 215000 660 6 6 URZ 2X000 BS88 Z 550 550 208000 660 400A 550 FMM 550 215000 660 6 6 URZ 2X000 BS88 Z 550 550 208000 660 450A 700 FMM 700 420000 660 6 6 URZ 2x000 BS88 Z 700 700 340000 660 500A 70...

Страница 25: ... 3 see wiring diagram Give auxiliary voltage supply to terminals 1 3 Thyristor unit doesn t go in conduction with input signal Green LED PWR light on and green LED ON in off condition No input signal Reversed polarities of input signal Reset contact in open condition see wiring diagram Provide to give input signal Reverse the input signal polarity Make link on reset terminals Load current flows al...

Страница 26: ...etted value This means that also with input signal in ON condition the unit is switched OFF and the system can not work at full power For these reason is important to control periodically the fan status checking that is rotating 9 4 Servicing In order to have correct cooling the user must clean the heatsink and the protective grill of fan The frequence of this servicing depends on environmental po...

Страница 27: ...User s Manual CD3000S 3PH from 125A to 500A Honeywell 25 www honeywell com imc ...

Страница 28: ...ria GmbH Phone 43 316 400123 FAX 43 316 40017 Belgium Honeywell SA NV Phone 31 0 205656999 FAX 31 0 165330746 Bulgaria Honeywell EOOD Phone 359 2 79 40 27 FAX 359 2 79 40 90 Czech Republic Honeywell spol s r o Phone 420 54324 5014 FAX 420 54324 5011 Denmark Honeywell A S Phone 45 39 55 55 55 FAX 45 39 55 55 58 Finland Honeywell OY Phone 358 3 2727625 FAX 358 3 2728600 France Honeywell SA Phone 33 ...

Отзывы: