APPLICATION

The C7772 series of Wallplate Temperature Sensors are 

designed to be used with the Excel 5000 family and other 

Honeywell controllers. The C7772 sensors provide a resistive 

output signal proportional to sensed room or space 

temperature. The C7772 is well suited for low-profile wall-

mounted applications where durability and tamperproof 

construction is desired, such as schools, prisons and 

institutions.

FEATURES

• Low profile when mounted on industry standard utility 

conduit box.

• Rugged, brushed stainless steel wallplate.
• Integral foam pad isolates wallplate sensor from 

conduit box.

• Insulated screw terminals ensure reliable field wiring 

connection.

• Models available with a variety of resistive temperature 

sensor elements.

Contents

Application ........................................................................

1

Features ...........................................................................

1

Specifications ...................................................................

2

Installation ........................................................................

2

Operation ..........................................................................

3

Checkout ..........................................................................

3

Содержание C7772 Series

Страница 1: ...ow profile wall mounted applications where durability and tamperproof construction is desired such as schools prisons and institutions FEATURES Low profile when mounted on industry standard utility conduit box Rugged brushed stainless steel wallplate Integral foam pad isolates wallplate sensor from conduit box Insulated screw terminals ensure reliable field wiring connection Models available with ...

Страница 2: ...use a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions 5 Follow local codes for installation and application IMPORTANT All wiring must agree with appl...

Страница 3: ...ibed below These must be avoided to assure proper operation 1 Do not route temperature sensor wiring with building power wiring next to control contactors near light dimming circuits electric motors or weld ing equipment 2 Avoid poor wiring connections 3 Do not mount sensor in an incorrect environment Connect the low voltage wiring from the controller terminals to the sensor screw terminals and ti...

Страница 4: ...ywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 customer honeywell com C7772A E WALLPLATE TEMPERATURE SENSOR U S Registered Trademark 2005 Honeywell International Inc 68 0213 2 B B Rev 08 05 ...

Отзывы: