D06G PRESSURE REGULATING VALVE
62-3051
4
Fig. 2. Adjusting outlet pressure.
MAINTENANCE AND REPAIR
Replacing D06G Cartridge
The working parts of the D06G Valve, including diaphragm,
valve seat, strainer, and disk, are all contained in a
replaceable cartridge. To replace the cartridge:
���
Close the supply valve and relieve the downstream
pressure.
���
Relieve pressure on the spring by loosening the locking
screw (do not remove) and turning the adjusting knob
counterclockwise until no resistance is felt.
���
Remove the bonnet (Fig. 3) by using the MT06A1009
or MT06A1017 Service Tool and turning
counterclockwise. Remove the spring and protection
washer (Fig. 4).
���
Remove the cartridge using two screwdrivers as levers
(Fig. 4). Remove the cartridge O-ring.
���
Remove the strainer cup (Fig. 5) using the MT06A1009
or MT06A1017 Service Tool.
���
Remove the strainer and strainer support. Remove the
U-seal.
���
Clean the inside of the valve and all the components.
NOTE:
Replace the U seal (provided in the repair kit)
for a complete cartridge repair.
���
Replace the U-seal by placing the U-seal on the
strainer support and pushing the assembly into place.
The U-seal open end must face the strainer support
(Fig. 7). Replace the strainer onto the strainer support.
���
Assemble the strainer cup O-ring onto the strainer cup
and insert the assembly into the body of the valve. Tighten
securely using the service tool. Do not over torque.
쐅
Replace the new cartridge ensuring the O-ring is in place.
쐈
Replace the protection washer with the lip up (away
from the valve body). See Fig. 6.
쐉
Replace the spring and bonnet. Tighten the bonnet
using the service tool. Do not over torque.
씈
Adjust the outlet pressure following the procedure in
Adjusting the Outlet Pressure section.
Fig. 3. Removing bonnet.
Fig. 4. Removing cartridge.
M12075
LOOSEN LOCKING SCREW
ONE TURN, BUT DO NOT
REMOVE SCREW OR
ADJUSTING KNOB.
INCREASE
DECREASE
TURN ADJUSTING
KNOB TO INCREASE
OR DECREASE
PRESSURE UNTIL
GAUGE INDICATES
DESIRED
PRESSURE.
TIGHTEN LOCKING
SCREW.
1
2
3
MAXIMUM INLET PRESSURE IS 400 PSI. OUTLET
PRESSURE RANGE IS 15 TO 130 PSI.
1
1
M11214
REMOVE BONNET USING
MT06A SERVICE TOOL
(ORDERED SEPARATELY) TO
TURN COUNTERCLOCKWISE.
M11212
REMOVE CARTRIDGE USING
TWO SCREWDRIVERS
AS LEVERS.
REMOVE SPRING
AND PROTECTION
WASHER.