Honeywell Braukmann D06G Скачать руководство пользователя страница 4

D06G PRESSURE REGULATING VALVE

62-3051

4

Fig. 2. Adjusting outlet pressure.

MAINTENANCE AND REPAIR

Replacing D06G Cartridge

The working parts of the D06G Valve, including diaphragm,
valve seat, strainer, and disk, are all contained in a
replaceable cartridge. To replace the cartridge:

���

Close the supply valve and relieve the downstream
pressure.

���

Relieve pressure on the spring by loosening the locking
screw (do not remove) and turning the adjusting knob
counterclockwise until no resistance is felt.

���

Remove the bonnet (Fig. 3) by using the MT06A1009
or MT06A1017 Service Tool and turning
counterclockwise. Remove the spring and protection
washer (Fig. 4).

���

Remove the cartridge using two screwdrivers as levers
(Fig. 4). Remove the cartridge O-ring.

���

Remove the strainer cup (Fig. 5) using the MT06A1009
or MT06A1017 Service Tool.

���

Remove the strainer and strainer support. Remove the
U-seal.

���

Clean the inside of the valve and all the components.

NOTE:

Replace the U seal (provided in the repair kit)
for a complete cartridge repair.

���

Replace the U-seal by placing the U-seal on the
strainer support and pushing the assembly into place.
The U-seal open end must face the strainer support
(Fig. 7). Replace the strainer onto the strainer support.

���

Assemble the strainer cup O-ring onto the strainer cup
and insert the assembly into the body of the valve. Tighten
securely using the service tool. Do not over torque.

Replace the new cartridge ensuring the O-ring is in place.

Replace the protection washer with the lip up (away
from the valve body). See Fig. 6.

Replace the spring and bonnet. Tighten the bonnet
using the service tool. Do not over torque.

Adjust the outlet pressure following the procedure in
Adjusting the Outlet Pressure section.

Fig. 3. Removing bonnet.

Fig. 4. Removing cartridge.

M12075

LOOSEN LOCKING SCREW 
ONE TURN, BUT DO NOT
REMOVE SCREW OR
ADJUSTING KNOB.

INCREASE

DECREASE

TURN ADJUSTING 
KNOB TO INCREASE
OR DECREASE 
PRESSURE UNTIL 
GAUGE INDICATES 
DESIRED 
PRESSURE.

TIGHTEN  LOCKING
SCREW.

1

2

3

MAXIMUM INLET PRESSURE IS 400 PSI. OUTLET 
PRESSURE RANGE IS 15 TO 130 PSI.

1

1

M11214

REMOVE BONNET USING
MT06A SERVICE TOOL
(ORDERED SEPARATELY) TO 
TURN COUNTERCLOCKWISE.

M11212

REMOVE CARTRIDGE USING
TWO SCREWDRIVERS 
AS LEVERS.

REMOVE SPRING
AND PROTECTION
WASHER.

Содержание Braukmann D06G

Страница 1: ...stallation and application FEATURES Noncorroding unitized cartridge contains all working parts and is easily replaceable Outlet pressure range from 15 to 130 psi in all models inlet rating 400 psi Includes built in strainer and thermal bypass Narrow design to accommodate restricted installation requirements Balanced seat construction provides superior pressure regulation Inlet and outlet are inter...

Страница 2: ... Design Balanced single seat Inlet Pressure Maximum 400 psi Reduced Pressure Range 15 to 130 psi all models Outlet Pressure Factory set at 60 psi Differential 14 psi minimum for optimum regulation Reduced Ratio 10 1 maximum Temperature Maximum 180 F 82 C Ambient Temperature Range 33 F to 140 F 1 C to 60 C Pipe Sizes Available 1 1 2 and 2 in Connections All models have internal NPT on inlet and out...

Страница 3: ...nting in the direction of water flow any mounting orientation is acceptable The D06G can be installed directly onto a pipe using the female NPT threads on each end or by using single or double unions if required One union is provided CAUTION Heat from soldering can damage internal parts Always remove tailpiece or solder adapter prior to soldering Open the supply valve slowly and open the downstrea...

Страница 4: ...seal by placing the U seal on the strainer support and pushing the assembly into place The U seal open end must face the strainer support Fig 7 Replace the strainer onto the strainer support Assemble the strainer cup O ring onto the strainer cup and insert the assembly into the body of the valve Tighten securely using the service tool Do not over torque 쐅 Replace the new cartridge ensuring the O r...

Страница 5: ...rainer support Do not remove the U seal Clean the strainer cup and the strainer Replace the strainer on the strainer support Insert the assembly into the valve Assemble the strainer cup O ring onto the strainer cup and insert the assembly into the body of the valve Tighten securely using the service tool Do not over torque M11215 REMOVE STRAINER CUP USING MT06A SERVICE TOOL BONNET ASSEMBLY SPRING ...

Страница 6: ...ssure is set the D06G automatically regulates to maintain the downstream pressure TROUBLESHOOTING Table 2 is a troubleshooting guide for the D06G Pressure Regulating Valves Table 2 Troubleshooting D06G Pressure Regulating Valves Problem Probable Cause Solution Will not hold pressure or pressure gradually rises a Thermal expansion b Debris on valve seat c Damaged valve seat a Install a thermal expa...

Страница 7: ... Union Kit NPT 1 1 2 in includes female NPT threaded tailpiece union nut and gasket and fits all 1 1 2 in D06 and DS06 Valves K06U5034 Union Kit Sweat 1 1 2 in includes sweat tailpiece union nut and gasket and fits all 1 1 2 in D06 and DS06 Valves K06U1045 Union Kit NPT 2 in includes female NPT threaded tailpiece union nut and gasket and fits all 2 in D06 and DS06 Valves K06U5042 Union Kit Sweat 2...

Страница 8: ...imited Honeywell Limitée 155 Gordon Baker Road North York Ontario M2H 2C9 Helping You Control Your World 62 3051 G H 11 96 Printed in U S A Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 www honeywell ca braukmann www sparco inc com ...

Отзывы: