2. Integrated Power and Low-noise Amplifier and Diplexer (IPLD)
Section
Condition
DO-160E Category
4
Temperature and Altitude—70 000ft
E1
4
Overpressure—200kPa
E1—Extended
4
Decompression—8000ft
E1—Extended
5.0
Temperature Variation—10°C/minute
A
6.0
Humidity
B
7.0
Operational Shocks and Crash Safety
E
8.0
Vibration
S (curves L, M, Y, C, E), R
(curves C1 and E1), and U
(curve G)
9.0
Explosion Proofness
E
10
Waterproofness
S
11
Fluid Susceptibility—tested with Ethylene, Glycol.
Isopropyl Alcohol, and one Fire Extinguishing agent
F
12
Sand and Dust
S
13
Fungus Resistance
F
14
Salt Spray
S
15
Magnetic Effect
Z
16
Power Input
A
17
Voltage Spike
A—Modified (600v, 10µs)
18
Audio Frequency Conducted Susceptibility—Power
Inputs
R—Modified
19
Induced Signal Susceptibility
ZC
20
Radio Frequency Susceptibility
RR
21
Emissions of RF Energy
H
22
Lightning Induced Transient Susceptibility
A3J33
23
Lightning Direct Effects
X—not required
24
Icing
A
25
Electrostatic Discharge
A—Modified
26
Fire, Flammability
C