SYSTEM SECURITY CODES
The systems provides one Installer code, one System Master code, plus a set of other user codes intended for other users of
the system. These codes can each be assigned one of 5 authority levels, which determine the functions each code can
perform as listed in the table below.
VISTA-20P: Provides 48 security codes (plus Installer code), including one System Master code, two Partition Master
codes, and 45 general user codes.
VISTA-15P: Provides 32 security codes (plus Installer code), including one System Master code and 31 general user codes.
Authority Levels
(can be assigned to users 03-49 only; users 1 and 2 cannot be changed)
Level
User No.
Functions
Installer
01
(default=4112) perform all security functions except can disarm only if used to arm; can
enter program mode; can change System Master code; cannot assign any other user codes
NOTE: For security purposes, the factory default installer code should be changed.
System Master
02
(default 1234) only one system master code per system; can perform all security functions,
add/delete users in either partition, change system master code, view event log, set system
clock, program keypad macro, program scheduled events, activate output devices
(triggers/relays)
Partition Master
(default)
P1 = 03
P2 = 33
VISTA-20P. Same as Master, except add/delete users limited to assigned partition only,
(these users can be assigned different authority levels, if desired; any user can be
assigned the partition master authority level)
0-User
03-49 (V20P)
03-33 (V15P)
perform security functions (arm, disarm, etc.) only; cannot add/delete users, view event log,
set system clock or program scheduled events
1-Arm Only
see
“
user
”
arm system only
2-Guest
see
“
user
”
can disarm the system only if it was used to arm the system
3-Duress
see
“
user
”
performs security functions, but also silently sends a duress message to the central station;
reports as duress code user number.
4-Partition Master see
“
user
”
VISTA-20P. See Partition Master paragraph above; used to assign other user numbers as
partition masters
Refer to the user guide for detailed procedures on adding/deleting security codes and changing user attributes.
The following is a brief description of how to add user codes.
Changing the System Master code...
Using Installer code: Installer code + [8] + 02 + new code
Using current System Master code: System Master code + [8] + 02 + new code + new code again
Adding a User Code:
Master code + [8] + 2-digit user no. + user
’
s code
Deleting a User Code:
Master code + [8] + 2-digit user no. + [#] [0]
Assigning Attributes:
Master code + [8] + 2-digit user no. + [#] [attribute no.] + value
Attributes:
Values
1 = Authority Level
0-4 (see Authority Level table above)
2 = Access Group
0-8 (0 = not assigned to a group)
3 = Active Partition(s)
1, 2, 3 (common)
for this user;
Enter partitions consecutively if more than one and press [#] to end the
entries.
4 = RF Zone No.
Assigns user number to button type zone for arm/disarm (
keyfob must be
enrolled in system first
; see
Wireless Key Templates
section).
5 = Open/Close Paging
1 for yes, 0 for no
–
38
–