80 Menu Mode
Output Funct. #
(00 = Quit)
01
Output Function No.
(VISTA-20P: 01-48
(VISTA-15P: 01-24)
[
∗
] to continue; 00 to quit
Enter the output function number to be defined (or 00 to exit)
01 A E P Trig
?00 0 0
–
ZL=00
Summary Screen
[
∗
] to continue
This screen displays a summary of the current output
programming (for this example, Zone List has been selected-this is
the default screen).
A
= Output Action;
E
= Triggering event;
P
= Partition;
Trig
= Trigger type
NOTE:
A question mark in the summary screen indicates that the
device number shown has not been mapped. Use *79 Menu mode
to map the device.
01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list (go to
“
A
”
)
2 = zone type (go to
“
B
”
)
3 = zone number (go to
“
C
”
)
[
∗
] to continue
Select where the initiating event for this output definition is to occur
as follows:
If you enter
“
0,
”
the following prompt appears:
Delete?
0 = NO, 1 = YES
Press 1 to delete this output definition. The system deletes the
output function and any previous programming.
A
”
01 Zn List
1
Zone List
01-08 = zone list
[
∗
] to continue
(prompt appears
if zone list was selected)
Enter the desired zone list number associated with this output
number. At the ENTER EVENT prompt, enter the zone list event
that will activate this output
NOTE:
Do not use pager zone lists 09-12 in output definitions.
Enter Event
0 = restore; 1 = alarm;
Alarm
1
2 = fault; 3= trouble
NOTE:
For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [
✱
] to continue and skip to the
“
Output Action
”
prompt.
“
B
”
01 Enter Zn type
Perimeter
03
Zone Type
See list at right for available
zone types.
(prompt appears
if zone type was selected)
Enter the desired zone type associated with this output number. At
the PARTITION prompt, enter the partition in which this zone type
will occur.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Day/Night
12 = Monitor Zone
01 = Ent/Exit #1
06 = 24 Hr Silent
14 = Carbon Monoxide
††
02 = Ent/Exit #2
07 = 24 Hr Audible
16 = Fire w/verification
03 = Perimeter
08 = 24 Hr Aux
23 = No Alarm Response
04 = Interior Follower
09 = Fire
24 = Silent Burglary
10 = Interior w/Delay 77 = Keyswitch Zone
81 = AAV Monitor Zone
90-91 = Configurable
CHOICES FOR
SYSTEM OPERATION:
20 = Arming
–
Stay
36 = **At Bell Timeout***
58 = Duress
21 = Arming
–
Away
38 = Chime
60 = AAV
22 = Disarming
39 = Any Fire Alarm
61 = AVS/GSMV
session begin
§
31 = End of Exit Time
40 = Bypassing
62 = AVS/GSMV
session end
§
32 = Start of Entry Time 41 = **AC Power Failure
66 = Function Key
†
33 = Any Burglary Alarm 42 = **System Battery Low 67 = Bell Fail
43 = Comm. Failure
68 = Telco Line Cut
52 = Kissoff
78 = Keyswitch Red LED
54 = Fire Zone Reset
79 = Keyswitch Green LED
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
†
Use *57 Menu Mode to assign the function key (function
“
07
”
).
††
when used with an output function, the carbon monoxide zone type
activates upon CO alarms only. Does not activate for trouble conditions.
§
automatically set when appropriate AVS Quick Command performed.
Note:
In normal operation mode:
Code + # + 7 + NN Key Entry
starts
Device NN.
Code + # + 8 + NN Key Entry
stops
Device NN.
Enter the partition in which this zone type will occur.
01 Partition
0 = any partition; 1 = partition 1;
Any partition 0
2 = partition 2; 3 = common
Press [
✱
] to continue and skip to the
“
Output Action
”
prompt.
–