01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[
∗
] to continue
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to “A” prompt)
2 = zone type (go to “B” prompt)
3 = zone number (go to “C” prompt)
If you enter “0,” the following prompt appears:
Delete?
Press 1 to delete this
0 = NO, 1 = YES
output definition
.
“
A
”
01 Zn List
1
Zone List
01-12 = zone list
[
∗
] to continue
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE:
Zone lists 09-12 can be used in output definitions if not used
for paging or for exit zone definition.
Press [
∗
] to continue.
Enter the zone list event that will activate this output.
Enter Event
0 = restore; 1 = alarm;
Alarm
1
2 = fault; 3= trouble
NOTE:
For alarm, fault, and trouble, an event on ANY zone in the
list activates the output.
Press [
∗
] to continue and skip to the “Output Action” prompt.
“
B
”
01 Enter Zn type
Perimeter 03
Zone Type
see list at right
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
06 = 24 Hr Silent
15 = Medical
01 = Ent/Exit #1
07 = 24 Hr Audible
16 = Fire w/verification
02 = Ent/Exit #2
08 = 24 Hr Aux
23 = No Alarm Response
03 = Perimeter
09 = Fire
24 = Silent Burglary
04 = Interior Follower
10 = Interior w/Delay
77 = Keyswitch
05 = Trouble Day/
12 = Monitor Zone
81 = AAV Monitor Zone
Alarm Night
14 = Gas
82 = Blockschloss
90-93 = Configurable
CHOICES FOR
SYSTEM OPERATION:
20 = Arming–Stay
41 = **AC Mains Failure
67 = Siren Fail
21 = Arming–Away
42 = **System Batt Low
68 = Telecom Line Cut
22 = Disarming
43 = Comm. Failure
69 = Telecom Line Restore
31 = End of Exit Time
46 = Sys Batt Restore**
70 = AC Mains Restore**
32 = Start of Entry Time
52 = Kissoff
71 = System Startup/Clock Not
33 = Any Burglary Alarm
54 = Fire Zone Reset
Set
36 = **At Siren Timeout***
58 = Duress
72 = Clock Set
38 = Chime
60 = AAV
78 = Keyswitch Red LED
39 = Any Fire Alarm
66 = Function Key†
79 = Keyswitch Green LED
40 = Bypassing
80 = Tamper Fault
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function “07”).
Note:
In normal operation mode:
Code + # + 7 + NN Key Entry
starts
Device NN.
Code + # + 8 + NN Key Entry
stops
Device NN.
Enter the partition in which this zone type will occur.
01 Partition
0 = any partition; 1 = partition 1;
Any partition
0
2 = partition 2; 3 = partition 3
Press [
∗
] to continue and skip to the “Output Action” prompt.
5-11
Содержание ADEMCO VISTA-48A
Страница 1: ...ADEMCO VISTA 48A ADEMCO VISTA 48E Security Systems Installation and Setup Guide K0749 1EN 11 04 Rev A ...
Страница 4: ......
Страница 28: ...Installation Instructions 3 8 ...
Страница 60: ...Installation Instructions 5 20 ...
Страница 75: ... NOTES 8 5 ...
Страница 76: ... NOTES Installation Instructions 8 6 ...