controller
The address allocation mode at the reader is
indicated by the bottom flashing green LED (lights
up briefly followed by a long pause).
Switch off the address allocation mode via the programming.
Activate address allocation mode
Activate
address
allocation
mode
via
the
programming (
).
Address allocation
mode indicator
6.2.3
Address indication
The address allocation mode must be activated.
The address indicator is for monitoring newly defined
addresses or for a later control.
- Tens digit:
Upper LED
(green)
Each flash indicates the tens digit of the allocated
address.
Example:
Flashes 2 x = 20
- Units digit:
Middle LED (yellow)
Each flash indicates the ones digit of the allocated address.
Example:
Flashes 4 x = 4
The address allocation mode is then displayed in the lower LED.
Repeat indication of addresses:
Hold the data carrier briefly in the reading range of the reader. A brief acoustical acknowledgement
confirms the request to indicate and restarts the indication sequence. The bottom LED remains dark
when the address is indicated.
Tens digit (green)
Units digit (yellow)
This example shows address 24
6.2.4
Manual address allocation via central control unit
Enter the serial number of a new reader plus the desired address when programming the central
control unit. The controller transmits the serial number plus the address to the reader. If the
received serial number corresponds with the number defined in the reader, the reader stores the
address.
Example:
serial number
+
address
Programming
Enter serial
number
of the operating unit
plus adress
serial number
+
address
ACS-8
IK3
DCM
RS-485
Mounting and Connection Instructions mifare/DESFire EV1 reader "Accentic" with/without keypad