 3 

  Install / Replace the Battery

 

IMPORTANT: 

ƒ

 

Use only lithium batteries. 

ƒ

 

Use four (4) lithium 1.5VDC AA cells.  (Energizer L91 or 
equivalent.) 

ƒ

 

Change all four batteries at the same time.  Do not mix 
weak batteries with new batteries. 

ƒ

 

Observe polarity. 

 

1.

 

If necessary, loosen the Captive 
Lock Screw and lift Cover off.  
Then, remove 4 screws that secure 
the Detector to the Back Box. 

2.

 

Observe the proper polarity and 
replace the batteries.  

Ensure 

positive side of battery is pointing 
away from the springs.

 

 

 

 4 

  Mount the Sensor

 

WALL MOUNTING

 

1.

 

Install the Back Box on the wall  
using two M4 x 20 mounting 
screws. 

 

UP

 

2.

 

Secure the Detector to the Back 
Box. 

3.

 

Fasten with four self tapping  
M3 x 14 screws.  

 

4.

 

Perform Settings & Adjustments. 

5.

 

Perform a Walk Test. 

6.

 

Secure the Cover with the M3 x 10 Captive Lock Screw.  

7.

 

Program the control panel. 

POLE MOUNTING

 

 

 

1.

 

Use a pole with an outside 
diameter of 43-48mm  
(1.69-1.89"). 

 

2.7- 4ft.
0.8 - 1.2m

 

2.

 

Attach the Brackets to the Back 
Box with two M3 x 8 screws. 

 

 

 

3.

 

Using the Pole Brackets 
and four M4 x 30 screws, 
fasten the Back Box to the 
pole. 

 

UP

 

4.

 

Secure the Detector to 
the Back Box and 
fasten with four self-
tapping M3 x 14 screws. 

5.

 

Perform Settings & 
Adjustments. 

6.

 

Perform a Walk Test. 

7.

 

Secure the Cover with 
the M3 x 10 Captive 
Lock Screw.  

8.

 

Program the control 
panel. 

 
 
 
 
 

You may have to move 
aside the sponge packing 
to reveal the screw holes. 

Содержание 5800PIR-RES

Страница 1: ...e ments from center up to 45 Sensitivity 2 0 C at 0 6m s 3 6 F at 2 0ft s Detection Speed 0 3 1 5m s 1 5ft s Operating Voltage 6 VDC uses 4 lithium 1 5VDC AA cells Battery Saving Timer Adjustable 120sec or 5sec Alarm Period 2 5 seconds LED Indicator Enabled during a walk test Disabled for normal operation Weatherproof IP54 compliance Operating Temperature 20 to 50 C 4 to 122 F Humidity 95 Max Acce...

Страница 2: ...0 mounting screws UP 2 Secure the Detector to the Back Box 3 Fasten with four self tapping M3 x 14 screws 4 Perform Settings Adjustments 5 Perform a Walk Test 6 Secure the Cover with the M3 x 10 Captive Lock Screw 7 Program the control panel POLE MOUNTING 1 Use a pole with an outside diameter of 43 48mm 1 69 1 89 2 7 4ft 0 8 1 2m 2 Attach the Brackets to the Back Box with two M3 x 8 screws 3 Using...

Страница 3: ...PER and LOWER beams are blocked detection is made Only the LOWER beam is blocked detection is not made Only the UPPER beam is blocked detection is not made Press and slide the Detection Length Adjustment Switch to the desired position A B C D DETECTION LENGTH D 02 0m 6 7ft C 05 0m 16 7ft B 08 0m 26 7ft A 12 0m 40 0ft NOTES This table is based on a motion sensor height of 1m 3 3ft The height of the...

Страница 4: ...itivity Best to prevent false detections High sensitivity Best detection catches increased false detections Use for applications where you are tagging video or need high security awareness 1 At the DIP switches set switch 2 for the desired Battery Saving Timer period Note The alarm output activations are limited by the timer selection 5 or 120 seconds Even if there are continuous alarm events the ...

Страница 5: ... when there is a big temperature difference between the moving object and the background If this causes a problem adjust the detection length to position B Then walk test to verify satisfactory results Approx 8m 27ft position B Approx 12m 40ft WALK TEST This sensor has a multi level detection pattern from side view A heat source beyond the detection area may cause the detector to issue a false ala...

Страница 6: ...orrectly Perform a Settings Adjustments procedure Low battery fault indicated on system keypad display Batteries are very low or dead Replace batteries Alarms when no one is walking through the detection area Sensor is not perpendicular to ground Remount and align sensor so the detection area is parallel to the ground Sensor is detecting moving trees bushes or a strong source of light Check for mo...

Страница 7: ...D Indicator Cover Lens Back Box Use four M4x30 screws if mounting to pole brackets or two M4x20 screws if mounting to wall Captive Lock Screw M3 x 10 Masking Strip Use as required Lens Holder UP DIP Switch Sensitivity Select Switch Detection Length Ajustment Switch Pole Bracket ...

Страница 8: ...ized changes or modifications could void the user s authority to operate the equipment DOCUMENTATION AND ONLINE SUPPORT For the latest documentation and online support information please go to http www security honeywell com hsc resources MyWebTech WARRANTY For the latest warranty information please go to http www security honeywell com hsc resources wa 2 Corporate Center Drive Suite 100 P O Box 9...

Отзывы: