Replacement Filters

Replacement filters may be purchased from the dealer where you purchased the
product. If you cannot locate a dealer in your area, please call our Consumer
Relations Dept. at (800) 332-1110 for assistance.

Select the proper replacement filter for your Honeywell HEPA air cleaner from the
chart below:

5100X

5150X

5200X

5250X

5300X

Kenmore 83154

21500

23500

24000

29500

32002 or 38002

33002 or 38002

34002 or 38002

35002 or 38002

Model No.

HEPA Filter 

Part Number

Carbon Pre-filter 

Part Number

Filter Replacement

With proper maintenance, your Honeywell air cleaner is designed to provide years
of high efficiency air cleaning. Your Honeywell air cleaner contains two filters: one 
activated carbon pre-filter and one primary HEPA filter.

The activated carbon pre-filter is the element of your air cleaner that helps reduce
normal household odors, captures lint and other large particles and helps protect 
the HEPA filter. It should be replaced at least every 3 months. If there are heavy 
concentrations of odors, smoke, or large particles in the home, you may need to
change the activated carbon pre-filter more often.

We DO NOT recommend operating the air cleaner without the activated carbon pre-
filter or without following the filter replacement guidelines. The HEPA filter may
become contaminated and begin to emit any odors captured.

The primary HEPA filter should remain effective for 1 to 3 years, depending upon the
environment in which the air cleaner is operating. Honeywell recommends changing
the HEPA filter based upon operating conditions - every 3 years for light usage, 2
years for normal usage and 1 year for heavy usage. The 53000 Model Air Cleaner
features a Change HEPA Filter monitor light which will glow when the HEPA filter
needs replacement.

If your air cleaner contains Filter Change Calendar wheels, please refer to the “Filter
Change Calendar” section for date wheel use instructions.

Our recommendations regarding filter replacement intervals are intended as guide-
lines only. Life expectancy of any filter media is dependent on the concentration of
the contaminants to which the system is exposed. If there are sources of large
amounts of contaminant generation (such as woodworking or heavy smoking) the
useful life of the filter media in your air cleaner may be reduced.

Whenever the air resistance of the HEPA filter becomes excessive due to the amount
of contaminants it has captured, the air volume output will begin to reduce and the
sound level of the air cleaner will increase somewhat. A completely blocked filter will 
cause a loud rumbling sound and almost no airflow.

4

Kenmore 83155, 83120, or Honeywell 38002

Содержание 51500

Страница 1: ...I III O The Science of Clean Air I II III O Portable Air Cleaners READ AND SAVE THESE INSTRUCTIONS I II 0 I II 0 I II 0 I II 0 Owner s Guide For Model Series 5100X 5150X 5200X 5250X 5300X Air Cleaners I II ...

Страница 2: ...location 10 To disconnect the air cleaner first turn speed control to OFF position and remove plug from the outlet 11 The air cleaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Locate air cleaner near power outlet and avoid using an ...

Страница 3: ...from the carton and plugged in Because it circulates air in a 360 pattern around the air cleaner it can be placed on the floor in almost any location However for best performance the air intake grille should not be blocked for at least 3 feet 1 meter in all directions Due to the large volume of air drawn towards the air cleaner surrounding areas should be cleaned and or vacuumed frequently to prev...

Страница 4: ...g upon use to indicate when filter replacement is necessary 5100X Series The Honeywell 5150X Series air cleaner is a 2 speed air cleaner operated by moving the speed control knob on the top panel from the Off O position to the high II position Allow the unit to operate for a few seconds at high speed then leave the control knob in the high position for faster more powerful room cleaning or move th...

Страница 5: ...t following the filter replacement guidelines The HEPA filter may become contaminated and begin to emit any odors captured The primary HEPA filter should remain effective for 1 to 3 years depending upon the environment in which the air cleaner is operating Honeywell recommends changing the HEPA filter based upon operating conditions every 3 years for light usage 2 years for normal usage and 1 year...

Страница 6: ...ter s being replaced Remove any packaging and plastic from the replacement filter s Step 7 Carefully wrap the pre filter around the HEPA filter so that the ends meet Fig 3 Fasten the ends together with the fastener provided Step 8 Place the whole filter assembly into the internal chamber Close the product by replacing the base and tightening the locking mechanism Step 9 Turn the air cleaner into a...

Страница 7: ... TERMS AND CONDITIONS If within one 1 year from the date of purchase this air cleaner fails due to a defect in material or workmanship Honeywell will repair or replace it free of charge or refund the purchase price less depreciation after reasonable efforts to repair This warranty applies only while this product is in use in Canada and in the United States This warranty gives you specific legal ri...

Отзывы: