Honeywell Sensing and Control
19
Limitless™ Series WLS Limit Switch
ISSUE 3
50054911
,
ATTENTION
RISk OF DEATH OR SERIOUS INJURY FROM EXPLOSION OR FIRE
Use only the following 3.6 V lithium thionyl chloride (Li-SOCl2) battery (non-rechargeable), size 2/3 AA. No other batteries are
approved for use in the WLS Series.
• Green Energy, ER14335M
• Honeywell, WBT1
WLS battery activation (see Figures 9 and 10):
Tools required: Slotted or Phillips screwdriver
Step
Action
1
If applicable, remove the two screws
on the housing cover.
2
Using a finger, press down slightly on the battery top
and remove the battery insulator
. Insure that the battery is prop-
erly seated and making good contact.
3
Replace cover and retighten screws or immediately proceed to Section 4.5 Pairing Mode.
Figure 9. Limitless™ WLS housing
Figure 10. Limitless™ WLS battery and Insulator
1
1
2
3