- 6 -

 

 

 

Step-by-Step 

Tech Support 

 Updated 7/27/10 

000 – No Announcement  

(See Below for word list)

 

 

 

 

 

Word 
Index 

Word 

Word 
Index 

Word 

Word 
Index 

Word 

Word 
Index 

Word 

 

 

 

 

 

 

 

 

116 AIR 

184 DOWNSTAIRS 

014 MEDICAL 

157 STORAGE 

255 ALARM 

130 DRIVEWAY 

212 MOTHERS 

154 SUN 

067 AND 

131 DUCT 

145 MOTION 

062 SYSTEM* 

117 APARTMENT 

   

   

   

161 APPLIANCE 

132 EAST 

165 NO 

158 TEMPERATURE 

118 AREA 

133 EQUIPMENT 

146 NORTH 

213 TOOL 

119 ATTIC 

004 EXIT 

012 NOT 

   

  

  

  

025 

UP 

120 BABY 

134 FACTORY 

011 OFF 

187 UPPER 

121 BACK 

211 FATHERS 

147 OFFICE 

183 UPSTAIRS 

122 BAR 

135 FENCE 

058 ON 

185 UTILITY 

021 BASEMENT 

040 FIRE 

148 OPEN 

   

051 BATHROOM 

029 FLOOR 

210 OUTSIDE 

215 WEST 

053 BATTERY 

137 FOYER 

   

017 WINDOW 

092 BED 

087 FRONT 

013 PANIC 

216 WING 

015 BEDROOM 

   

090 PARTITION 

   

123 BLOWER 

023 GARAGE 

149 PATIO 

002 ZONE 

124 BOILER 

138 GAS 

061 PHONE 

   

162 BRIGHT 

139 GLASS 

063 POWER 

069 0 

125 BUILDING 

   

166 PUMP* 

070 1 

039 BURGLARY 

050 HALL 

   

136 1

ST

  

010 

HEAT 

088 

REAR 

071 

003 CALL 

   

028 RIGHT 

056 2

ND

089 CENTRAL 

209 INSIDE 

018 ROOM 

072 3 

054 CHIME 

   

   

159 3

RD

126 CLOSED 

022 KITCHEN 

007 ‘S 

073 4 

127 COMPUTER 

   

150 SERVICE 

217 4

TH

  

140 

LAUNDRY 

151 

SHED 

218 

208 DAUGHTER’S 

027 LEFT 

152 SHOP 

075 5

TH

052 DEN 

141 LIBRARY 

153 SIDE 

219 6 

128 DETECTOR 

019 LIGHT 

024 SMOKE 

076 6

TH

060 DEVICE 

030 LIVING 

223 SON’S 

220 7

TH

163 DIM 

142 LOADING 

155 SOUTH 

077 8 

031 DINING 

094 LOWER 

006 STAIRS 

221 8

TH

016 DOOR 

143 MACHINE 

156 STATION 

078 9 

008 DOWN 

144 MASTER 

157 STORAGE 

222 9

TH

Figure 6: Thermostat Descriptors 

 

 

 

10 

Thermostat #2 Enable and Address 

00 

 

00 – Thermostat #2 disabled 
02 – Thermostat #2 enabled and set to address 2 

 

 

 

 

11 Thermostat 

#2 

Swing 

1,4 

 

Digit #1: Swing above set point 
Digit #2: Swing below set point 

 

 

See Figure 5 above

 

 

 

 

 

 

 

12 

Announce the Thermostat #2 Temperature 

 

0 – Do not announce thermostat #1 Temperature 
1 – Announce thermostat #1 temperature as part of the status report. 

 

 

 

 

Содержание 4286

Страница 1: ...supported 2 DSL requires an RJ31X DSL filter Wiring Notes 1 When using a power supply you MUST share a common ground with the control panel 2 The 4286 wires up directly to the keypad Terminals on your Control panel 3 Observe the panels ECP keypad data wire runs and do not exceed the 2000 max distance the panel offers 1500 on vista20 and lower control panels 4 Existing wires connected to the Handse...

Страница 2: ...Support Updated 7 27 10 Figure 2 Vista 40 50 128b bp 250bp Figure 3 Vista 32fb 128fb fbp 250fbp System Programming Notes 1 The 4286 has a Non Changeable address of 04 and can not be changed See below for programming on various panels ...

Страница 3: ... 2 digit access code Enter 1 9 for Customers with out an answering machine or a dedicated line to the panel If they have an answering machine you can use the Answering Machine Defeat option by Entering 15 here This requires the customer to call let ring once hang up and call back 4 10 15 20p Notes 4286 Phone Modules must have software version WA4286 15 1 V101 or higher refer to the label on the sq...

Страница 4: ...the telephone keypad Upon Doing so the panel will start speaking the 1st programming location and it value It will say Field 00 is 00 Programming can only be accessed within 3 hours of power up After programming the 98 mode you only have 15 minutes to re access it If it has been longer than that you can simply power the 4286 down for 5 seconds then back up and you have your 3 hour time window agai...

Страница 5: ... 0 50 0 30 3 0 75 0 40 3 0 75 0 40 4 1 00 0 60 4 1 00 0 60 5 1 50 0 80 5 1 50 0 80 6 2 00 1 10 6 2 00 1 10 7 2 50 1 40 7 2 50 1 40 Figure 5 Swing Points Do Not Select a 1 1 This field defines how many degrees below the set point the heat will turn on and how many degrees above the set point the heat will turn off These values also define the swing of the air conditioner operation 06 Announce the T...

Страница 6: ...IGHT 139 GLASS 063 POWER 069 0 125 BUILDING 166 PUMP 070 1 039 BURGLARY 050 HALL 136 1ST 010 HEAT 088 REAR 071 2 003 CALL 028 RIGHT 056 2ND 089 CENTRAL 209 INSIDE 018 ROOM 072 3 054 CHIME 159 3RD 126 CLOSED 022 KITCHEN 007 S 073 4 127 COMPUTER 150 SERVICE 217 4TH 140 LAUNDRY 151 SHED 218 5 208 DAUGHTER S 027 LEFT 152 SHOP 075 5TH 052 DEN 141 LIBRARY 153 SIDE 219 6 128 DETECTOR 019 LIGHT 024 SMOKE ...

Страница 7: ...onnecting power to the thermostat 4 While installation of the 4500 is possible without the services of a HVAC contractor some installers will prefer to have an HVAC contractor connect the 4500 to the HVAC system and test its operation This is recommended if you do not have HVAC experience In cases where you prefer to do the entire installation it is suggested that the HVAC contractor be contacted ...

Страница 8: ... adjust the temperature It has a Thermistor built on it that detects the temperature of the room When it determines that the temperature is above or below the set back it opens up the relay to prevent voltage feed to HVAC system preventing it from coming on at existing thermostat setting it then uses 4500 settings When temperature reaches Set back setting Relay will close to allow the on premise t...

Страница 9: ...ting for thermostat 1 will follow You can change its set point using menu selection 1 below If thermostat 1 is in BYPASS or CHECK that status will be announced instead of the set point The 4286 will also announce whether set back has been turned off by the user Menu Selections To change temperature enter 1 This selection is used to set the armed away set back temperature for thermostats 1 or 2 Thi...

Страница 10: ...on where the 4500 is mounted is free of drafts Temperature in the room swings too widely when the 4500 is set to ACTIVE mode 1 Decrease the amount of span as described in the section Programming the 4286 to add 4500 thermostats in Section 4 of the manual Also see figure 7 above for programming locations Troubleshooting the 4286 Problem When I enter the phone code on premise the operator comes on o...

Страница 11: ...plug on the 4286 and not the plug intended for the 4500 make sure it is plugged in with yellow towards the center of the board Meter for voltage or data at the harness and on the pins when pulled back a little Take everything else off the ECP buss and test again to confirm there is not a current overload or address conflict 4 Tones generated by phone are not long enough or not correct Hold the key...

Отзывы: