3 - 16
Reset Scanner and Base/Access Point
Once the power level is set, you must scan the
Reset Base
bar code and
wait for the scanner to unlink and relink to a base or an Access Point.
Once that is done, scan the
Reset Scanner
bar code and wait for the base
or Access Point to unlink and relink to the scanner.
Batch Mode
Batch mode is used to store bar code data when a scanner is out of range of its
base or Access Point, or when performing inventory. The data is transmitted to
the base or Access Point once the scanner is back in range or when the records
are manually transmitted.
Note: Batch mode has limitations when using multiple scanners to one base or
Access Point. If a cordless system is being used in "multiple link mode,"
where up to 7 scanners are to be connected to one base or Access Point,
some accumulated or batched scans could be lost if scanners are
constantly being moved in and out of range.
Automatic Batch Mode
stores bar code data when the scanner is out of range
of the base or Access Point. The data is automatically transmitted to the base
or Access Point once the scanner is back in range. When the scanner’s buffer
space is full, any bar codes scanned generate an error tone. In order to scan
bar codes again, the scanner must be moved back into range of the base or
Access Point so data can be transmitted.
Inventory Batch Mode
stores bar code data, whether or not you are in range of
the base or Access Point. To transmit the stored data to the base or Access
Point, either place the scanner in the base, or scan
(page 3-21). When the scanner’s buffer space is full, any bar codes scanned
generate an error tone. In order to scan bar codes again, the data must be
transmitted to the base or Access Point.
: * : R E S E T _ . ³
Reset Scanner
Reset Base
Содержание 1900GSR-2
Страница 1: ... Xenon 1900 1902 Area Imaging Scanner User s Guide ...
Страница 12: ...CCB01 010BT Base Item Number Serial Number and Revision Information location Compliance Label location ...
Страница 60: ...2 28 ...
Страница 93: ...3 33 ESC 8 Razz or error tone to indicate a decode communication to host was unsuccessful Command Action ...
Страница 94: ...3 34 ...
Страница 136: ...6 12 ...
Страница 212: ...8 20 ...
Страница 220: ...9 8 ...
Страница 226: ...10 6 ...
Страница 274: ...12 8 ...
Страница 280: ...13 6 ...
Страница 291: ......
Страница 292: ......
Страница 295: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message ...
Страница 296: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...
Страница 298: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 Xenon UG Rev B 6 10 ...