COMPONENT MAINTENANCE MANUAL
15-0705
TESTING AND FAULT ISOLATION
1.
Planning Data
(TASK 33-30-15-99C-801-A01)
A.
Reason for the Job
(Subtask 33-30-15-99C-002-A01)
(1)
Use the test procedures in this section to test and isolate faults.
(2)
The function of the test procedures is to find if there is a failure in the operation of the door
mounted cargo loading light.
B.
Job Setup Data
(Subtask 33-30-15-99C-003-A01)
(1)
You can use equivalent alternatives for the special tools, fixtures, equipment, and consumable
materials unless specified differently. The user must find equivalent alternatives.
(2)
Refer to Table 1001 for the specified special tools, fixtures, and equipment in this section.
(3)
CAGE codes and manufacturers’ addresses are available at https://cage.dla.mil.
Table 1001. Special Tools, Fixtures, and Equipment
Number
Description
Source
variable regulated power supply
(0-30 VDC, 6 amperes minimum)
commercially available
Fluke 8010A
digital multimeter (0 to 200 volts, 0
to 2,000 milliamps, 1.0% accuracy)
CAGE: 89536
WARNING:
BEFORE YOU USE A MATERIAL, REFER TO THE MANUFACTURERS’ MATERIAL
SAFETY DATA SHEETS. SOME MATERIALS CAN BE DANGEROUS.
CAUTION:
DO NOT USE MATERIALS THAT ARE NOT EQUIVALENT TO HONEYWELL
SPECIFIED MATERIALS. MATERIALS THAT ARE NOT EQUIVALENT CAN
CAUSE DAMAGE TO THE EQUIPMENT AND CAN MAKE THE WARRANTY NOT
APPLICABLE.
(4)
Refer to Table 1002 for the specified consumable materials in this section.
Table 1002. Consumables
Number
Description
Source
A-A-59323
cleaning cloth (MIL-C-85043 Type
1)
commercially available
(5)
The list that follows identifies Honeywell publications that are related to this section:
• Not applicable.
EFFECTIVITY
ALL
33-30-15
Page 1001
30 Mar 2017
© Honeywell International Inc. Do not copy without express permission of Honeywell.