GB-14
D
GB
F
NL
I
E
8
6
7
9
11
10
▷
Tighten the nuts in a crosswise fashion, torque:
3.5 Nm.
14
12
13
Torque for
ECOMAX
®
0 – 3: 18 Nm,
ECOMAX
®
4 – 5: 35 Nm.
Fibre gasket
only for
LFR 0 – 3 C.
ECOMAX
®
. .M, ECOMAX
®
. .P, ECOMAX
®
. .F
2
1
3
4
Check the
recuperator.
WARNING
The body insulation is made of ceramic fibres (RCF).
Wear protective equipment. Safety data sheet avail-
able on request.
▷
To replace the recuperator, remove the burner,
place it vertically and secure it to prevent it falling
over. The gas insert must be removed to avoid
breaking the ceramic combustion chamber when
placing the burner.
▷
We recommend that the body insulation be re-
placed when fitting a new recuperator.
b
a
9
7
5
6
8
10
11
12
▷
Place the new recuperator vertical and secure
it to prevent it falling over.
b
a
9
7
5
6
8
10
11
12
Hold the body
insulation
together, e.g.
using adhe-
sive tape.
▷
Tighten the nuts in two cycles in a crosswise
fashion, torque: 3.5 Nm.
13
14
▷
Tighten the nuts in two cycles in a crosswise
fashion. Torque for ECOMAX
®
1 – 3: 18 Nm,
ECOMAX
®
4 – 5: 35 Nm.
Ensure that the
flue gas insula-
tion is installed
in the correct
position.
a < b