background image

 

4

3

2

1

12

11

10

9

8

7

6

5

4

3

2

1

14

13

Z8

GND

Z7

Z6

GND

Z5

Z4

GND

Z3

Z2

GND

Z1

GND

Z9

GND

GND

15.

5V IN

5800C2W-001-V1

12V

AUX

+

EOLR

RED

Zone Calibration Button

Not Used

BLACK

-

+

Integral

Fuse

(+)

To Backup Battery,
Battery must read a
minimum 9.5VDC
before the charging
circuit will initiate

Refer to LED Functions

SW1

SW2

OBSERVE 

POLARITY

Provides 11.2VDC ±15% @ 100mA
to supply PIR motion, or glassbreak
sensors.  
(Minimum voltage is 10.5VDC)

Zone 1 of 9

shown wired

 

 

 
IMPORTANT:

 The first battery test occurs 1 hour after power up.  To quickly verify a good backup battery, 

unplug and then plug back in the power supply; the system will perform a battery test within 1 minute 

NOTES:

 

  All zones that are used MUST 

have an EOL resistor.  

  EOL resistor values must be 

from 1k to 10k ohms. (Nine 
2.2k ohm resistors are 
included for those panels not 
using any resistors.)  

  If the existing installation 

zones have EOL resistors 
(from 1k to 10k ohms) they 
may remain. 

  For a NC loop without an EOL 

resistor, you must add one in 
series with the loop. Preferably 
it should be located at the end 
of the loop furthest away from 
the control panel for proper 
supervision. 

 

  For a NO loop without an EOL 

resistor, you must add one in 
parallel (across) the loop.  
Preferably it should be located 
at the end of the loop furthest 
away from the control panel for 
proper supervision. 

 

 

SPECIFICATIONS 

Dimensions 

Length 7.0 in. (178mm), Width 4.5 in. (114mm) ,Depth 1.5 in. (38mm) 

Mounting Hardware 

Double stick tape and screws included. 

Operating Temperature 

+14 to +140°F  (– 10 to +60°C) 

Humidity 

95% RH Max. 

Transmission Range 

Up to 300ft.  (91 meters) 

Operating Voltage 

Supplied by plug-in transformer 15.5VDC (± 5%) @ 1A (P/N: 300-07052, or 300-07102 Canada) 

Battery Backup 

Use 12V, 4Ah battery such as Resideo 467, Yuasa NP4-12, Casil CA1240 or equivalent.  Provides 4 hours of backup.   
Battery is to be located in the existing control panel. DO NOT use batteries of larger capacity. 

Tamper Detection 

Activated when the cover is removed. 

5800C2W Supervision 

  low battery 

  backup battery power 

  each enrolled zone transmits a supervisory message every 72 minutes 

LED Status Indicators 

(The input power indicator is viewable 
through the enclosure cover.) 

  input power 

  backup power 

  wireless transmission 

Input Zones 

(9 hardwired)

 

All zones that are used must have an EOL resistor.  (Refer to the back page for detailed information.) 

Auxiliary Output 

(12VAUX) 

Provides 11.2VDC ±15% @ 100mA to supply PIR motion, or glassbreak sensors.  

 

FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS 

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or 
modifications could void the user's authority to operate the equipment. 

CLASS B DIGITAL DEVICE STATEMENT 

This equipment has been tested and found to comply with the limits for a Class B digital device, as defined by FCC Rules Part 15.105. The Class B Digital Device 
statement can be viewed at: 
https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx 

FCC / IC STATEMENT 

This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 
Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux conditions suivantes: (1) 
Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception 
indésirable. 

 

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center Drive., Melville, NY 11747, 
Ph: 516-577-2000 

 

The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-
of-life equipment will help prevent potential negative consequences for the environment and human health. 

 

Any attempt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly prohibited 

 

SUPPORT & WARRANTY INFORMATION 

For the latest documentation and online support information, please go to: 

www.resideo.com 

For the latest warranty information, please go to: 

https://www.security.honeywellhome.com/warranty

 

 

 

The Honeywell Home Trademark is used under license from Honeywell International Inc. 

This product manufactured by Resideo and its affiliates. 

 

Ê800-15422ESŠ 

800-15422E   9/13   Rev. E

 

 

2 Corporate Center Drive, Suite 100 

P.O. Box 9040, Melville, NY 11747 

 2020 Resideo Technologies, Inc. 

www.resideo.com

 

 

 

LED 

Function 

Note

: LEDs are shown as they appear on the circuit board.

 

#1

 

Red (blinking) – Module needs calibrating.   
Green – Module is calibrated. 

#2

 

Green – DC power (15.5VDC, ± 5%) from the plug-in transformer is present. 
Red – DC power is NOT present.  
(Viewable through the enclosure cover.) 

#3

 

Yellow – Low battery or No battery. 
When the battery voltage drops to 11.2VDC, a low battery message is sent to the control panel and LED 3 turns yellow.  
When the battery voltage drops to 9.5VDC, the battery is disconnected.  The battery will not connect again until AC is restored. 

#4

 

Green (blinking) – RF signal transmission. 

Отзывы: