11
Connect the discharge hose.
Never attempt to operate the pump without priming water, or the
pump will overheat. Extended dry operation will destroy the pump
seal. If the unit has been operated dry, stop the engine immediately
and allow the pump to cool before adding priming water.
Check the priming water.
Priming water capacity:
2.
3.
WT20X:
WT30X, WT40X:
WATER
DISCHARGE HOSE
HOSE BAND
PRIMING WATER FILLER CAP
Use a commercially available hose, hose connector, and hose band. A
short, large-diameter hose is most efficient. Long or small-diameter
hose increases fluid friction and reduces pump output.
Tighten the hose band securely to prevent the hose from
disconnecting under high pressure.
The pump chamber should be primed with full of water before
operating.
15.0 L (3.96 US gal, 3.30 lmp gal)
14.0 L (3.70 US gal, 3.08 lmp gal)
Содержание WT20X
Страница 9: ... 6 C and UD types WT30X WT40X WT20X French labels come with the water pump ...
Страница 48: ...MANUEL DE L UTILISATEUR Honda WT20X WT30X WT40X Notice originale ...
Страница 55: ... La pompe à eau comporte des étiquettes en français Types C et UD WT20X WT30X WT40X 6 ...
Страница 94: ...BEDIENUNGSANLEITUNG Honda WT20X WT30X WT40X Originalbetriebsanleitung ...
Страница 101: ... 6 WT30X WT40X WT20X Typen C und UD Die Wasserpumpe ist mit Plaketten auf Französisch versehen ...
Страница 140: ...MANUAL DE EXPLICACIONES Honda WT20X WT30X WT40X Manual original ...
Страница 147: ... La bomba de agua se sirve con etiquetas en francés español WT30X WT40X WT20X Tipos C y UD 6 ...
Страница 194: ...K3 WT40X K4 WT20X WT30X KS 36YG0620 00X36 YG0 6202 Honda Motor Co Ltd 2012 1000 2012 06 Printed in Japan C N 西 独 仏 英 HC ...