background image

7

Step 1

Inspection: Your pump has been carefully packaged to prevent damage

during shipping. However, occasional damage does occur due to rough handling.
Carefully inspect the pump for damage that could cause it to fail.

Step 2:

Attach desired length of PVC or ABS discharge pipe to pump outlet,

using PVC adapter (1

1

/

4

" pipe and adapter for WSP33AA, 1

1

/

2

" WSP53AA, 

WSP73AA). Make sure open end of pipe will be above top of basin.

Step 3:

Clear sump basin of any water, debris or sediment.

Step 4:

Lower pump into basin.

Step 5:

Attach in line check valve to discharge pipe 12" to 18" above pump 

discharge with arrow pointing away from the pump (with the flow). Connect
other end of check valve securely to drain pipe and tighten clamps.

Note:

Do not put check valve directly into pump discharge opening.

Step 6:

Drill a 1/8" relief hole in the discharge pipe 5" above pipe connection to 

pump.

Step 7:

Plug in pump and fill sump basin with water to test unit. Pump should

turn on at 13" to 14" water level. Allow pump to go through several ON-OFF
cycles to assure satisfactory operation.

Note:

If pump does not operate properly, see the troubleshooting checklist on 

page 1

4

.

Septic Tank  Installation

The WSP pumps can be used to pump septic tank effluent (not containing
greater than 3/8'' solids), but must be installed as follows:
• Install pump in separate compartment at the discharge side of the septic 

tank. Never install pump in main tank where sludge collects.

• Use with a junction box.

WARNING:

Sump basin must be vented in accordance with local plumbing

codes. These pumps are not designed for and CANNOT be installed in loca-
tions classified as hazardous in accordance with the National Electric Code,
ANSI/NEPA 70-1984.

Installation Instructions

0204 HONDA WSP manual.qxd  3/24/2004  2:14 PM  Page 9

Содержание WSP33AA

Страница 1: ...OPERATOR S MANUAL 2003 American Honda Motor Co Inc All Rights Reserved SUBMERSIBLE PUMP WSP33AA WSP53AA WSP73AA 2004 American Honda Motor Co Inc All Rights Reserved BY...

Страница 2: ...eview the recommendations outlined within this operator s manual Please contact your supplier supplying dealer or contractor if service is necessary or if you have any questions or need further assist...

Страница 3: ...the pump Elevate the pump with bricks or other support above the sump pit or pond bottom if debris is present Clean filter basin when cleaning inlet filter media when pump is shutdown If used with a...

Страница 4: ...e for normal lifting Please note that this will help prevent damage due to inadvertent lifting of the pump by the power cord Rope attached to automatic pump for lifting and installation Rope attached...

Страница 5: ...cut a hole in the basement floor and excavate for the sump Plumbing and electrical contractors can advise on proper installations of drain tiles sump pump and electrical service Honda recommends that...

Страница 6: ...not designed to handle raw sewage see page 9 Septic Tank Installation Do not attempt to adapt one for this type of application A sewage ejector pump especially designed to handle solids must be used...

Страница 7: ...t after completion of cleaning 2 Pour enough water into the sump to cycle the pump and assure its proper functioning Annually Remove and clean the pump Clean the sump pit also 5 WARNING Before handlin...

Страница 8: ...driver Pipe wrench Adjustable wrench medium large Hacksaw with 24 tooth blade for cutting plastic pipe Knife or round file for smoothing inside of all plastic pipe connections General Specifications...

Страница 9: ...nto pump discharge opening Step 6 Drill a 1 8 relief hole in the discharge pipe 5 above pipe connection to pump Step 7 Plug in pump and fill sump basin with water to test unit Pump should turn on at 1...

Страница 10: ...professionals 3 CALL AN ELECTRICIAN WHEN IN DOUBT Pump should be connected to a separate 15 amp circuit breaker or 15 amp fuse block Plugging into existing outlets may cause low voltage at motor caus...

Страница 11: ...eck Valve Tools Needed for all pump installations Pipe wrench slot screwdriver 24 tooth hacksaw knife or round file Step 1 Thread male PVC adaptor into pump discharge opening Step 2 Cement a 15 piece...

Страница 12: ...wer position so that the pump turns on at the 13 to 14 water level Step 6 Perform several ON OFF cycles to assure satisfactory operation FLOAT CORD CLIP MOVE CORD UP OR DOWN Performance Table Capacity...

Страница 13: ...on level Grounded type 115 volt receptacle min height above floor 4 ft 133 8 Turn off level Lifting handle Mechanical float switch All equipment other than pump to be supplied by others Pump only sup...

Страница 14: ...uously for an extended period of time in a dry condition or at the lowest water level the motor protector will be activated in single phase units Constant repetition of this action will shorten pump s...

Страница 15: ...tted Carbon Ceramic WSP53AA and WSP73AA Material Lower Side Viton Fitted Silicon Carbide Silicon Carbide WSP53AA and WSP73AA Impeller Type Semi Open Bearing Sealed Ball Bearing Motor Air filled Insula...

Страница 16: ...g cord Check for clogged vent hole in pump case Vertical pumping distance is too high Reduce distance or resize pump Inlet holes in pump base are clogged Remove pump and clean the openings Impeller or...

Страница 17: ...accumulation on the float remove pump from sump and clean float switch Wipe all water and dirt from the pump and float switch Be sure float switch operates freely after cleaning Cleaning impeller and...

Страница 18: ...Lifting Hanger 304 Stainless AISI 304 1 244 Strainer 304 Stainless AISI 304 1 262 Float Switch 1 801 Rotor 1 802 Stator 1 809 Capacitor 1 811 Submersible Cable 1 814 Motor Frame 304 Stainless AISI 304...

Страница 19: ...hanical seal 1 set 120 Connection Band 304 Stainless AISI 304 1 200 Lifting hanger 304 Stainless AISI 304 1 244 Strainer 304 Stainless AISI 304 1 262 Float switch 1 801 Rotor 1 802 Stator 1 809 Capaci...

Страница 20: ...73AA 5 Remove the mechanical seal from the main shaft Note 2 Be careful not to cut your fingers on the shaft key groove when pulling out the mechanical seal Note 3 Be careful not to scratch or bend th...

Страница 21: ...on made by the dealership s management you may contact the Honda Power Equipment Customer Relations Office You can write to American Honda Motor Co Inc Power Equipment Division Customer Relations Offi...

Страница 22: ...0204 HONDA WSP manual qxd 3 24 2004 2 14 PM Page 24...

Страница 23: ...Printed on Recycled Paper PRINTED IN U S A POM53680 IPC 2200 2005 04 P N 31WSP602...

Отзывы: