39
OPERATION
3. Connect the black lead of battery charging cable into the negative
(–) DC terminal of the generator.
4. Connect the red lead of the battery charging cable to the positive (+)
battery terminal and the black lead to the negative (–) battery
terminal.
5. Start the generator.
Do not start the vehicle while the battery charging cable is connected
and the generator is running. The vehicle or the generator may be
damaged.
An overloaded DC circuit, excessive current drawn by the battery, or a
wiring problem will trip the DC circuit protector (the yellow indicator
inside the clear circuit protector button will pop out). If this happens,
wait a few minutes before pushing in the circuit protector button to
resume operation. If the circuit protector continues to go OFF,
discontinue charging and see your authorized Honda generator dealer.
The DC circuit protector does not prevent overcharging the battery.
Disconnecting the battery charging cable:
1. Stop the engine.
2. Disconnect the black lead of the battery charging cable from the
negative (–) battery terminal.
3. Disconnect the red lead of the battery charging cable from the
positive (+) battery terminal.
4. Disconnect the battery charging cables from the DC terminals of the
generator.
5. Connect the vehicle battery ground cable to the negative (–) battery
terminal.
DC CIRCUIT PROTECTOR
OFF
ON