5. STARTING THE ENGINE
CAUTION:
When starting the generator after adding fuel for the first time, after
long-term storage, or after running out of fuel, turn the fuel valve lever
to the ON position, then wait for 10 to 20 seconds before starting the
engine.
Before starting the engine, disconnect any load
from the AC receptacle.
1. Make sure that the AC circuit breaker is in the
OFF position. The generator may be hard to
start if a load is connected.
2. Turn the fuel valve lever to “ON”.
I “ON”
3. Pull the choke adjustment lever to the left
NOTE: It may not be necessary to shut down
the choke when starting a warm engine.
4. Turn the engine switch “ON”
Start the engine: slowly pull the recoil starter
until it is engaged, and then pull it quickly.
5. Turn the choke adjustment lever back to the
running position (turn right) after starting.
6. Allow the engine to get warm before placing
the generator under load.
1.
2.
3.
4.
CAUTION:
• The starter grip can be drawn back very quickly before you release
it. This may pull your hand forcefully toward the engine and cause
an injury.
• Do not allow the starter grip to snap back. Return it slowly by hand.
• Do not let the starter rope rub against the generator body, or the
rope will wear out prematurely.