background image

Honda Motor Europe Ltd.

EM2300

OWNER’S MANUAL

Original Instructions

Содержание EM2300

Страница 1: ...Honda Motor Europe Ltd EM2300 OWNER S MANUAL Original Instructions...

Страница 2: ...ecial attention to statements preceded by the following words Indicates a strong possibility of severe personal injury or death if instructions are not followed If a problem should arise or if you hav...

Страница 3: ...3 COMPONENT IDENTIFICATION 9 4 PRE OPERATION CHECK 11 5 STARTING THE ENGINE 15 6 GENERATOR USE 17 7 STOPPING THE ENGINE 20 8 MAINTENANCE 21 9 TRANSPORTING STORAGE 26 10 TROUBLESHOOTING 28 11 SPECIFICA...

Страница 4: ...stop the generator quickly in case of emergency Understand the use of all generator controls output receptacles and connections Be sure that anyone who operates the generator receives proper instruct...

Страница 5: ...from the weather check all of the electrical components on the control panel before each use Moisture or ice can cause a malfunction or short circuit in electrical components that could result in ele...

Страница 6: ...l the fuel tank Never smoke near gasoline and keep other flames and sparks away Always store gasoline in an approved container Make sure that any spilled fuel has been wiped up before starting the eng...

Страница 7: ...els and safety notes and precautions described in this manual carefully If a label comes off or becomes hard to read contact your Honda dealer for a replacement 1 2 3 Connect Caution Read Owner s Manu...

Страница 8: ...in a dangerous amount of exhaust gas Never run your generator inside a garage house or near open windows or doors Improper connections to a building s electrical system can allow current from the gene...

Страница 9: ...and authorized representative are written in the EC Declaration of Conformity CONTENT OUTLINE in this Owner s Manual Noise Label Performance Class IP Code Quality Class Dry Mass Name and address of au...

Страница 10: ...fler 8 Spark plug 9 Choke adjustment lever 10 Recoil starter 11 Fuel valve lever 12 Air filter cover Record the frame serial number and the engine serial number in the spaces below You will need these...

Страница 11: ...er starting the engine keep your hands away from the switch immediately AC Circuit Breaker The AC Circuit breaker non fuse breaker will shut off automatically when the load exceeds the generator rated...

Страница 12: ...re use Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range 1 Remove the oil filler cap dipstick and wipe the dipstick clean 2 Check...

Страница 13: ...in a well ventilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored Do not overfill the fuel tank as it may ov...

Страница 14: ...cohol gasohol be sure its octane rating is at least as high as that recommended by Honda There are two types of gasohol one containing ethanol and the other containing methanol Do not use gasohol that...

Страница 15: ...cleaner cover clips remove the air cleaner cover and remove the air cleaner element Clean or replace the element if necessary see page 23 CAUTION Never run the engine without the air filter element Ra...

Страница 16: ...ment lever to the left NOTE It may not be necessary to shut down the choke when starting a warm engine 4 Turn the engine switch ON Start the engine slowly pull the recoil starter until it is engaged a...

Страница 17: ...odifications Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 300 meter 1 000 foot increase in altitude The affect of altitude on the horsepower will be...

Страница 18: ...reaker with overload protection of 30 mA ground fault detection and cut off of less than 0 4 seconds at more than 30 A of output current if you are using two or more appliance Follow the instructions...

Страница 19: ...ts on the control panel before each use Moisture or ice can cause a malfunction or short circuit in electrical components that could result in electrocution Do not alter the internal wiring of the gen...

Страница 20: ...disconnect the appliance and examine it for signs of malfunction Be sure all electric devices are OFF before plugging them in within the rated output of the generator and within the receptacle rated c...

Страница 21: ...devices plugged into the generator are turned OFF Stop the engine using below sequence 1 Turn the circuit breaker to OFF 2 Turn the engine switch to STOP 3 Turn the fuel valve lever to OFF NOTE When...

Страница 22: ...e Honda Genuine parts or their equivalent Use of replacement parts may damage the generator or cause personal injury REGULAR SERVICE PERIOD 1 Perform at every indicated month or operating hour interva...

Страница 23: ...rubber If damaged replace it immediately 1 drain plug 2 washer 3 ring 5 Put the drain plug back Torque 17 6 Nm 13 ft lbf 6 Add the correct oil to the reservoir to the full position 4 7 Put the dipstic...

Страница 24: ...gine wear will result 1 Unsnap the two air cleaner cover clips remove the air cleaner cover and remove the air cleaner element 2 Clean in warm soapy water rinse and allow to dry thoroughly Or clean in...

Страница 25: ...g time the sediment cup should be cleaned 1 Turn the engine switch to the STOP position 2 Turn the fuel valve lever to the OFF position Remove the sediment cup and O ring 3 Clean the sediment cup in n...

Страница 26: ...led Clean the spark plug with a wire brush if it is to be reused 5 Measure the plug gap with a feeler gauge Correct as necessary by carefully bending the side electrode The gap should be 0 7 0 8 mm 0...

Страница 27: ...e Take the generator off the vehicle and use it in a well ventilated place Avoid a place exposed to direct sunlight when putting the generator on a vehicle If the generator is left in an enclosed vehi...

Страница 28: ...the oil then reinstall the spark plug 10 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves ar...

Страница 29: ...e Add the recommended oil see page 11 NO YES Is the spark plug in good condition Clean readjust gap and dry the spark plug Replace it if necessary see page 25 NO YES Is the fuel reaching the carbureto...

Страница 30: ...he AC circuit breaker ON see page 19 NO YES Check the electrical appliance or equipment for any defects Take the generator to your servicing dealer NO DEFECTS Replace the electrical appliance or equip...

Страница 31: ...on Level B DC Output NO Engine Model Honda GX160H Engine Type Forced air cooled 4 stroke OHV Transistor Displacement cc 163 Cylinder diam x stroke mm 68x45 Compression Ratio 8 5 1 Starting System Reco...

Страница 32: ...this cannot be used reliably to determine whether or not further precautions are required Factors that influence the actual level of exposure of work force include the characteristics of the work roo...

Страница 33: ...32 12 WIRING DIAGRAM...

Страница 34: ...o Ltd No 7 Houyou Road Fuxing Economic Development Zone Fuzhou City Fujian Province P R China 4 Authorized representative and able to compile the technical documentation Honda Motor Europe Ltd Cain Ro...

Отзывы: