Содержание EB6500

Страница 1: ......

Страница 2: ......

Страница 3: ...s are not followed Indicates a strong possibility Ehat serious injury or death may result if instructions are not followed CAUTION indicates a possibility that rnino injury could result if instruction...

Страница 4: ...ENGINE 12 5 GENERATOR USE 17 6 STOPPING THE ENGINE 25 0 High altitude operation 26 7 MAINTENANCE 27 8 TRANSPORTING STORAGE 36 9 TROUBLESHOOTING 38 10 WIRING DIAGRAM 40 11 SPECIFICATIONS 41 12 HANGER...

Страница 5: ...mponents which could result in electrocution l Do not connect to a building s electrical system unless an isolation switch has been installed by a qualified electrician Fire and Burn Hazards l The exh...

Страница 6: ...before operating the generator The labels should be considered as permanent parts of the generator If a label comes off or becomes hard to read contact an authorized Honda generator dealer for replace...

Страница 7: ...5...

Страница 8: ...IL ALERT LAMP HANGER ENGINE SWITCH I VOLTAGE SELECTOR SWITCH AC CIRCUIT I REAKER AC RECEPTACLES GROUND TERMINAL WHEEL AIR CLEANER FUEL VALVE ENGINE OIL FILLER CAP AUTO THROTTLE SWITCH 1 ENGINE OIL DRA...

Страница 9: ...UG CAP FRAME SERIAL NUMBER BATTERY TRAY Record the engine and frame serial numbers for your future reterence Refer to these serial numbers when ordering parts and when making technical or warranty inq...

Страница 10: ...tainer rs 30 20 10 0 10 SAE low 30 is recommended for general all temperature use Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated ran...

Страница 11: ...gasoline or an oil gasoline mixture Avoid getting dirt dust or water in the fuel tank Use of a lower octane gasoline can cause persistent pinging or heavy spark knock a metallic rapping noise which if...

Страница 12: ...by Honda There are two types of gasohol one containing ethanol and the other containing methanol Do not use gasohol than contains more than 10 ethanol Do not use gasoline containing methanol methyl o...

Страница 13: ...ir cleaner elements to be sure they are clean and in good condition Clean or replace the element if necessary page 30 f iieiq Never run the engine without the air cleaner Rapid engine wear will result...

Страница 14: ...G THE ENGINE 1 Make sure that the AC circuit breaker is in the OFF position The generator may be hard to start if a load is connected AC ClRCiJlT BREAKER 2 Turn the fuel valve to the ON position FUEL...

Страница 15: ...ke rod out to the CLOSED position NOTE Do not use the choke if the engine is warm or if the air temperature is high CHOKE ROD 4 Make sure the auto throttle switch is OFF or more time will be required...

Страница 16: ...switch to the ON position ENGINE SWITCH Pull the starter grip lightly until resistance is felt then pull briskly riiEiq Do not allow the starter grip to snap back against the engine Return it gently t...

Страница 17: ...han 5 seconds can damage the motor If the engine fails to start release the switch and wait 10 seconds before operating the starter again l If the speed of the starter motor drops after a period of ti...

Страница 18: ...o the OPEN position as the engine warms up CHOKE RO 8 If you wish to use the auto throttle system turn the auto throttle switch to the AUTO position after the engine has warmed up for 2 or 3 minutes A...

Страница 19: ...contact the lines during a power outage and when utility power is restored the generator may explode burn or cause fires in the building s electrical system GROUND TERMINAL l Limit operation requiring...

Страница 20: ...ed At OFF the auto throttle system does not operate NOTE l AUTO is recommended to minimize fuel consumption when no load is applied l The auto throttle system will not respond to electrical loads of l...

Страница 21: ...re the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically stop the engine the engine switch will remain in the ON position If the Oil Alert system stops the...

Страница 22: ...exceed the rated load capacity of the circuit before switching the circuit breaker ON again CIRCUIT BREAKER Circuit Protector The circuit protectors will automatically switch OFF it the individual cir...

Страница 23: ...protection against electrical shock TEST BUTTON RESET BUTTON To test depress the TEST button see page 22 To restore power depress the RESET button see page 23 Perform this test monthly to ensure prope...

Страница 24: ...rform the GFCI test monthly Record your test on the GFCI test card provided on the fuel tank 1 Unplug all appliance s from the GFCI receptacles 2 Start the engine 3 Turn the circuit breaker ON 4 Make...

Страница 25: ...an authorized Honda generator dealer RESET BUTTON 7 When the RESET BUTTON extends during operation l Unplug all appliance s from the GFCI protected receptacle l Press the RESET BUTTON IF THE GFCI CAN...

Страница 26: ...exceed the maximum load capacity Substantial overloading will switch off the circuit breaker Marginal overloading may not switch off the circuit breaker but it will shorten the service life of the ge...

Страница 27: ...E To stop the engine in an emergency turn the engine switch to the OFF position In normal use 1 Turn the AC circuit breaker to the OFF position AC CIRCUIT BREAKER 2 Move the engine switch to the OFF p...

Страница 28: ...ate the engine at altitudes higher than 6 000 feet above sea level have an authorized Honda generator dealer perform this carburetor modification Even with suitable carburetor jetting engine horsepowe...

Страница 29: ...s well ventilated Exhaust gas con tains poisonous carbon monoxide Use only genuine HONDA parts or their equivalent for maintenance or repair Replacement parts which are not of equivalent quality may d...

Страница 30: ...erating hour interval whichever NOTE 1 Service more frequently when used in dusty areas 2 This service should be performed by an authorized Honda generator dealer unless the owner has the proper tools...

Страница 31: ...r oil may cause skin cancer if repeatedly left in contact with the skin for prolonged periods Although this is unlikely unless you handle used oil on a daily basis it is still advisable to thoroughly...

Страница 32: ...ating the generator in extremely dusty areas Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion Use only soapy water or nonflammable solvent Never run the ge...

Страница 33: ...sh in nonflammable or high flash point so lvent Allow the element to dry thoroughly 3 Soak the element in clean engine oil and squeeze out the excess oil The engine will smoke during inital start up i...

Страница 34: ...ediment cup should be cleaned 1 Turn the fuel valve to the OFF position Remove the sediment cup 2 Clean the cup thoroughly 3 Check to be sure the O ring is in place and reinstall the sediment cup Afte...

Страница 35: ...e the spark plug cap 2 Clean any dirt from around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark pulg 4 Visually inspect the spark plug Discard it if the insulator i...

Страница 36: ...a new spark plug tighten l 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tighten l 8 l 4 turn after the spark plug seats to compress the washer l The spar...

Страница 37: ...intain its efficiency Clean the spark arrester as follows 1 Loosen the screw by the exhaust port of the muffler and remove the spark arrester 2 Use a brush to remove carbon deposits from the spark arr...

Страница 38: ...ed fuel may ignite Before storing the unit for an extended period 1 Be sure the storage area is free of excessive humidity and dust 2 Drain the fuel a With the fuel valve OFF remove and empty the sedi...

Страница 39: ...ablespoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil then reinstall the spark plug 5 Slowly pull the starter grip until resistance is felt At this...

Страница 40: ...lug cap Clean any dust from around the spark plug base then remove the spark plug b Install the spark plug in the plug cap c Turn the engine switch on d Grounding the side electrode to any engine grou...

Страница 41: ...dry before starting the engine Fuel vapor or spilled fuel may ignite DRAIN SCREW 7 If the engine still does not start take the generator to an authorized Honda dealer B When the engine starts but sto...

Страница 42: ...IO WIRING DIAGRAM...

Страница 43: ...on Ratio Engine Speed Cooling System Ignition System Oil Capacity Fuel Tank Capacity Soark Plua Gk390 389 cm3 23 7 cu in r88 x 64 mm 3 5 x 2 5 in 8 0 1 3600 r p m Forced air Transistorized magneto 1 l...

Страница 44: ...TALLATION 1 Remove the upper frame Install the hanger on it and install the upper frame on the body BRACKET HANGER FRAME NOTE Install at near center avoiding to install over the fuel filler cap FUEL F...

Страница 45: ...Install the axle assembly on the generator using two bolts and nuts 3 Install the two stands on the under frame WHEELS 4 Remove the upper frame Install the two handles with brackets on it using six b...

Страница 46: ...to the starter solenoid 3 Connect the ground cable to the generator rear housing 4 Set the battery on the battery tray and secure with the battery bracket Connect the starter cable to the battery pos...

Страница 47: ...STARTER SoLEINo D STARTER CABLE positive STARTER CABLE I BATTERY BRACKET GUARD PLATE BATTERY TRAY BATTERY GUARD 45...

Страница 48: ...problem still has not been resolved to your satisfaction contact American Honda Motor Co Inc P O Box 100021 Duluth Georgia 30136 9421 Telephone 404 497 6400 We will need the following information in...

Страница 49: ...is way If you are dissatisfied with the decision made by the dealership s management contact the Honda Power Equipment Customer Relations Office You can write American Honda Motor Co Inc Power Equipme...

Страница 50: ...MEMO 47...

Страница 51: ...MEMO 48...

Страница 52: ......

Страница 53: ......