41
SERVICING YOUR GENERATOR
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete
draining.
1.Turn the engine switch and fuel filler cap vent lever to the OFF
position (see page 25) to reduce the possibility of fuel leakage.
2.Loosen the maintenance cover screw and remove the maintenance
3.Place a suitable container next to the engine to catch the used oil.
4.Remove the oil filler cap, and drain the oil into the container by
tipping the engine toward the oil filler neck.
Improper disposal of engine oil can be harmful to the environment. If
you change your own oil, please dispose of the used oil properly.
Put it in a sealed container, and take it to a recycling center. Do not
discard it in a trash bin, dump it on the ground, or pour it down the
drain.
5.With the generator in a level surface, fill with the recommended oil to
the upper limit of the oil filler neck (see page 42).
Maximum oil capacity:
13 oz (0.40 L)
6.Reinstall the oil filler cap securely.
7.Reinstall the maintenance cover and tighten the maintenance cover
screw securely.
Wash your hands with soap and water after handling used oil.
OIL FILLER NECK
UPPER LIMIT
31Z398000.book 41 ページ 2013年8月1日 木曜日 午後4時36分
Содержание EB2000i
Страница 11: ...9 GENERATOR SAFETY 31Z398000 book 9...
Страница 89: ...87 MEMO 31Z398000 book 87...
Страница 90: ...88 MEMO 31Z398000 book 88...