Battery

The battery contains sulfuric acid (electrolyte) which is highly
corrosive and poisonous.

Getting electrolyte in your eyes or on your skin can cause serious
burns.

Wear protective clothing and eye protection when working near the
battery.

WARNING:

Wash hands after handling.

Emergency Procedures:

Battery posts, terminals, and related accessories contain

lead and lead compounds.

Eyes

Flush with water from a cup or other container for at least 15

minutes (water under pressure can damage the eye). Immediately call
a physician, local poison control, or 911.

Skin

Remove contaminated clothing. Flush the skin with large

quantities of water. Call a physician immediately.

Swallowing

Drink water or milk. Call your local poison control center

or a physician immediately.

08/02/29 15:22:54 31Z08610_052

Содержание EB11000

Страница 1: ......

Страница 2: ...uded in this publication were in effect at the time of approval for printing Honda Motor Co Ltd reserves the right however to discontinue or change specifications or design at any time without notice...

Страница 3: ...ded to help you avoid damage to your generator other property or the environment We suggest you read the warranty policy to fully understand its coverage and your responsibilities of ownership The war...

Страница 4: ...ety information in a variety of forms including on the generator preceded by a safety alert symbol and one of three signal words DANGER WARNING or CAUTION These signal words mean be or if you don t fo...

Страница 5: ...CI 16 Hour Meter 20 Auto Throttle Switch 20 Ground Terminal 21 Oil Alert System 21 GENERATOR USE 22 Connections to a Building s Electrical System 22 Ground System 22 Special Requirements 22 AC Applica...

Страница 6: ...Air Cleaner Service 43 Spark Plug Service 45 Spark Arrester Maintenance 47 Fuel Sediment Cup Cleaning 48 Fuel Filter 49 Fuse Replacement 50 Battery 51 TRANSPORTING STORAGE 56 TROUBLESHOOTING 60 WIRING...

Страница 7: ...LOCATIONS If a label comes off or becomes hard to read contact your Honda generator dealer for a replacement These labels warn you of potential hazards that can cause serious injury Read them carefull...

Страница 8: ...6 08 02 29 15 18 11 31Z08610_007...

Страница 9: ...ts by being familiar with your generator s controls and by observing safe operating procedures Know how to stop the generator quickly in case of emergency Understand the use of all generator controls...

Страница 10: ...nents that could result in electrocution The exhaust system gets hot enough to ignite some materials Keep the generator at least 3 feet 1 meter away from buildings and other equipment during operation...

Страница 11: ...PONENT IDENTIFICATION TOP COVER AIR CLEANER OIL FILLER CAP FUEL VALVE RECOIL STARTER GRIP OIL DRAIN BOLT FUSE FRAME SERIAL NUMBER BATTERY CONTROL PANEL FRONT COVER OIL FILTER 08 02 29 15 18 30 31Z0861...

Страница 12: ...EVEL DIPSTICK MUFFLER Record the engine and frame serial numbers and date of purchase for your future reference Refer to these serial numbers when ordering parts and when making technical or warranty...

Страница 13: ...TOR 30A 120V GFCI RESET BUTTON GFCI TEST BUTTON CIRCUIT PROTECTORS 30A 120V 240V AC RECEPTACLES 120V 20A AC RECEPTACLES 120V 30A ENGINE SWITCH CIRCUIT BREAKER AC RECEPTACLE 120V 240V 50A 43 8A Max AC...

Страница 14: ...ngine by operating the starter motor To start the engine pull the starter grip lightly until resistance is felt and then pull briskly Return the key to the ON position once the engine has started Do n...

Страница 15: ...nk to the carburetor Be sure to return the fuel valve lever to the OFF position after stopping the engine The choke knob opens and closes the choke valve in the carburetor Pulling the choke knob to th...

Страница 16: ...he AC circuit breaker may be used to switch the generator AC power ON or OFF Check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching th...

Страница 17: ...t protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at the 120V 20A 120V 30A locking plug or 120 240V 30A locking plug receptacle If a cir...

Страница 18: ...has TEST and RESET buttons and is connected to the circuit breaker An example of ground fault current is the current that would flow through a person who is using an appliance with faulty insulation...

Страница 19: ...ords tools and appliances or double insulated tools and appliances Inspect cords and plugs and replace if damaged Do not use cord lengths greater than 164 feet 50 meters and do not use multiple tools...

Страница 20: ...ways check GFCI operation before using the generator Unplug all tools and appliances from the generator Start the engine Turn the circuit breaker to the ON position Turn the Auto Throttle switch to th...

Страница 21: ...not function as described take the generator to an authorized Honda generator dealer for repair During generator use if the GFCI RESET button extends and the circuit breaker trips this usually indicat...

Страница 22: ...hen appliances are turned on or reconnected the engine returns to the rated speed Recommended to minimize fuel consumption and further reduce noise levels when no load is applied to the generator The...

Страница 23: ...ng jurisdiction for local codes or ordinances that apply to the intended use of the generator The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the c...

Страница 24: ...he AC output receptacles The system ground is connected to the AC neutral wire There may be Federal or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances th...

Страница 25: ...nces or power cords can create a potential for electrical shock Before connecting an appliance or power cord to the generator The total power requirements VA of all appliances connected must be consid...

Страница 26: ...quire more than their rated wattage for startup Do not exceed the current limit specified for any one receptacle If an overloaded circuit causes the AC circuit breaker or circuit protector to switch O...

Страница 27: ...main power producing circuits These two circuits supply equal power to different receptacles shown Receptacle 2 has a 17A load connected to it Receptacle 3 has a 28A load connected to it Both recepta...

Страница 28: ...ating speed check that the appliance does not exceed the rated load capacity of the generator To avoid extended warm up periods keep the switch OFF until the engine reaches operating temperature The A...

Страница 29: ...This engine when operated at high altitude with the carburetor modifications for high altitude use will meet each emission standard throughout its useful life Even with carburetor modification engine...

Страница 30: ...el surface and the engine switch is in the OFF position Use 4 stroke motor oil that meets or exceeds the requirements for API service category SJ or later or equivalent Always check the API SERVICE la...

Страница 31: ...engine has been running allow it to cool first Refuel carefully to avoid spilling fuel Do not fill above the upper limit Never refuel the engine inside a building where gasoline fumes may reach flames...

Страница 32: ...than 10 ethanol E10 or 5 methanol by volume In addition methanol must contain cosolvents and corrosion inhibitors Use of fuels with content of ethanol or methanol greater than shown above may cause s...

Страница 33: ...rks If the electrolyte level is near the LOWER level remove the battery filler caps and carefully add distilled water to the upper level line see page Eyes Flush with water from a cup or other contain...

Страница 34: ...h To prevent a possible fire keep the generator at least 3 feet 1 meter away from building walls and other equipment during operation Do not place flammable objects close to the engine Operating this...

Страница 35: ...ls to start release the switch and wait 10 seconds before operating the starter again If the speed of the starter motor drops after a period of time it is an indication that the battery should be rech...

Страница 36: ...ECK see page If you wish to use the Auto Throttle system turn the Auto Throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes Push the choke knob to the OPEN position as...

Страница 37: ...rgency turn the engine switch to the OFF position Turn off the main switch of all the appliances connected to the generator Turn the AC circuit breaker to the OFF position Turn the fuel valve lever to...

Страница 38: ...intenance schedule routine inspection procedures and simple maintenance procedures using basic hand tools Other service tasks that are more difficult or require special tools are best handled by profe...

Страница 39: ...ou can decide whether or not you should perform a given task Make sure the engine is off before you begin any maintenance or repairs This will eliminate several potential hazards Operate outside away...

Страница 40: ...oval or alteration of any part of the intake fuel or exhaust systems Altering or defeating the governor linkage or speed adjusting mechanism to cause the engine to operate outside its design parameter...

Страница 41: ...vice The emission control systems on your Honda engine were designed built and certified to conform with applicable emission regulations We recommend the use of Honda Genuine parts whenever you have m...

Страница 42: ...se log hours of operation to determine proper maintenance intervals Engine oil Engine oil filter Air filter Battery electrolyte Spark plug Spark arrester GFCI operation Idle speed Valve clearance Comb...

Страница 43: ...in a sealed container to your local service station or recycling center for reclamation Do not throw it in the trash pour it on the ground or pour it down a drain Open the top cover to access the oil...

Страница 44: ...pecified amount of the recommended oil see page 28 41 Reinstall the oil filler cap dipstick Start the engine and check for oil filter leaks Stop the engine and check the oil level as described on page...

Страница 45: ...r regularly Service more frequently when operating the generator in extremely dusty areas Open the top cover to access the air cleaner Release four latch tabs from the air cleaner cover and remove the...

Страница 46: ...rushing will force dirt into the fibers Replace the paper air filter if it is excessively dirty Foam air filter Clean in warm soapy water rinse and allow to dry thoroughly Or clean in nonflammable sol...

Страница 47: ...An incorrect spark plug can cause engine damage If the engine has been running let it to cool before servicing the spark plug Remove the spark plug caps Clean any dirt from around the spark plug base...

Страница 48: ...e spark plug washers are in good condition and thread the spark plugs in by hand to prevent cross threading After the spark plugs are seated tighten with a spark plug wrench to compress the washer A l...

Страница 49: ...spark arrester must be serviced every 100 hours to maintain its efficiency Use a brush to remove carbon deposits from the spark arrester screen Inspect the screen for breaks or tears and replace it i...

Страница 50: ...up prevents dirt or water that may be in the fuel tank from entering the carburetor If the engine has not been run for a long time the sediment cup should be cleaned Turn the engine switch to the OFF...

Страница 51: ...L FILTER If the fuel filter is found with excessive water accumulation or sediment take the generator to your servicing dealer Check the fuel filter for water accumulation or sediment 1 2 08 02 29 15...

Страница 52: ...dental short circuiting Remove the fuse holder cover and replace the fuse Use only fuses with rating that specified Never use a fuse with a different rating from that specified Serious damage to the e...

Страница 53: ...dures Battery posts terminals and related accessories contain lead and lead compounds Eyes Flush with water from a cup or other container for at least 15 minutes water under pressure can damage the ey...

Страница 54: ...ve the front cover to access the battery Remove the negative cable from the battery negative terminal then remove the positive cable from the battery positive terminal Remove the battery set plate Rem...

Страница 55: ...own below Install the battery tray in the generator and the battery on the tray Make sure the battery is on the edge of the battery tray near the fuse holder Install the battery set plate Install the...

Страница 56: ...y seems to be weak causing slow starting or other electrical problems see your authorized Honda generator dealer Remove the front cover and the battery see page 52 Check the electrolyte level in each...

Страница 57: ...r should be used that can be adjusted to deliver 2 4 amps The generator s engine has an approximate 3 amp charging system to charge the battery while the engine is running If the generator is only use...

Страница 58: ...hot engine and exhaust system can burn you and can ignite some material Take care not to drop or strike the generator when transporting Do not place heavy objects on the generator When transporting t...

Страница 59: ...ne and add gasoline stabilizer Fill with fresh gasoline and add gasoline stabilizer Drain the carburetor float bowl page 59 Drain the fuel sediment cup page 48 Fill with fresh gasoline and add gasolin...

Страница 60: ...y outdoors Wipe up spills immediately Drain the fuel Remove the fuel tank cap and empty the fuel tank into an approved gasoline container using a commercially available hand siphon Reinstall the fuel...

Страница 61: ...e container Tighten the carburetor drain screw securely Change the engine oil see page 43 Remove the two spark plugs and pour about a tablespoon of clean engine oil into the cylinders Crank the engine...

Страница 62: ...etor If the engine still does not start take the generator to an authorized Honda generator dealer Turn OFF the engine switch and loosen the drain screw Fuel should flow from the drain when the engine...

Страница 63: ...Check the electrical ap pliance or equipment for any defects Turn the AC circuit breaker ON Reset the circuit protector Take the generator to an au thorized Honda generator dealer Replace the electric...

Страница 64: ...62 WIRING DIAGRAM 08 02 29 15 24 03 31Z08610_063...

Страница 65: ...ENSO 6 9 US gal 26 1 48 US qt 1 40 9 5 kVA 10 5 kVA Refer to page 45 See your authorized Honda dealer Model Type Length Width Height Dry weight Model Engine Type Displacement Bore Stroke Engine Speed...

Страница 66: ...rough Helm Inc at 1 888 292 5395 or visit www hondapowerequipment com This manual provides complete illustrated parts lists Available through your Honda dealer Your authorized Honda power equipment de...

Страница 67: ...ll problems are solved in this way If you are dissatisfied with the decision made by the dealership s management contact the Honda Power Equipment Customer Relations Office You can write to American H...

Страница 68: ...ocator Information 65 Honda Publications 64 GENERATOR SAFETY 5 Important Safety Information 7 Safety Label Locations 5 GENERATOR USE 22 AC Applications 23 AC Operation 24 AC Receptacle Selection 25 Au...

Страница 69: ...42 Spark Arrester Maintenance 47 Spark Plug Service 45 PRE OPERATION CHECK 28 Battery 31 Engine Oil 28 Fuel Recommendations 30 Refueling 29 SPECIFICATIONS 63 STARTING THE ENGINE 32 STOPPING THE ENGINE...

Страница 70: ...68 MEMO 08 02 29 15 24 40 31Z08610_069...

Страница 71: ......

Отзывы: