Servicing Your Honda
41
Subframe
4. Connect the negative (–) terminal (11) to the
battery (12).
Tighten the negative (–) terminal bolt (13) to
the specified torque:
1.5 lbf·ft (2.0 N·m, 0.2 kgf·m)
5. Make sure that the air cleaner box and the air
cleaner connecting tube are correctly
connected and tighten the air cleaner
connecting tube clamp screw (14) so the
distance between the clamp ends is 0.24 - 0.35
in (6 - 9 mm).
6. Connect the breather tube (15) and IAT sensor
connector (16).
7. Connect the starter/ignition relay connector
(17) and install the seat support base (18).
8. Install and tighten the collars (19), and seat
support base mounting bolts (20) to the
specified torque:
7 lbf·ft (10 N·m, 1.0 kgf·m)
9. Tighten the right and left muffler mounting A
bolts, and install the right and left exhaust
springs A, (page 133). (CRF450RWE only)
10. Install the left and right mufflers (page 127).
11. Install the right and left shrouds (page 36,
12. Install the seat (page 34).
(11) negative (–) terminal
(12) battery
(13) negative (–) terminal bolt
(12)
(11)
(13)
(14) air cleaner connecting tube clamp screw
(15) breather tube
(16) IAT sensor connector
(15)
(14)
0.24 - 0.35 in (6 - 9 mm)
(14)
(16)
(17) starter/ignition relay connector
(18) seat support base
(19) collars
(20) seat support base mounting bolts
(17)
(18)
(20)
(19)
Содержание CRF450R 2020
Страница 3: ...2020 Honda CRF450RX CRF450R CRF450RWE OWNER S MANUAL COMPETITION HANDBOOK ...
Страница 19: ...14 Before Riding BLANK PAGE ...
Страница 143: ...138 Servicing Your Honda BLANK PAGE ...
Страница 175: ...170 Taking Care of the Unexpected BLANK PAGE ...
Страница 189: ...184 Technical Information BLANK PAGE ...
Страница 194: ...Consumer Information 189 BLANK PAGE ...