Homing KEY MASTER Скачать руководство пользователя страница 6

key master A2.5 Version Manual      www.hominggame.com 

 

 

5

Exit

 

14

TEST Button

In the appointed mode state,Use this button to test or 

shift

 

 

 

7.Account Checking 

The way to 

check account

 :press

 

Mode

 

button, said enter mode one when the LED1 light on .Continue to press 

Mode

 button, said enter mode two when the LED2 light on .And so on...... 

Mode 1

Shows Total amount of inserted coins 

Mode 2---Shows Total amount of gift payout 

Notice: 

There are permanent data(Total inserted coins quantity and Total gifts given out quantity) store in the 

mainboard, can not through the 

clear

 way to delete ,except the motherboard broken. 

 

How to check these permanent data ? 

 

the way is as follows: 

 

1. Press the 

Mode

 button to select the 

Mode 8

 (LED 8 light

) .Shows 

8F - - - - 

 

 

 

 

2.Press the 

Enter

 button, appear

 

8A0000

 

 

3.

Use the 

UP

 and 

DOWN

 button to imput the permanent data account checking password.The factory Default 

setting password is

 

0003

,

press the

 

enter

 button to confirm

 

 

4.

will shows the LED1 and LED8 are on at the same time, the digital tube will shows the total amounts of insterted 

coins quantity,such as the following picture shows 

000608

,Means the total amount inserted coins is 608 pcs 

 

5. 

press the 

Test

 

button, will shows the LED2 AND LED8 are on at the same time, the digital tube will shows the 

total amount of gifts given out quantity.Such as the following pictures shows 

000004

,means the total mount of 

gifts given out is 4 pcs. 

 

Содержание KEY MASTER

Страница 1: ...key master A2 5 Version Manual www hominggame com sales hominggame com whatsapp 8618688409495 KEY MASTER Manual A2 5...

Страница 2: ...6 Mother board s function 4 7 Account checking 5 8 Adjusting and testing 6 9 9 Winning probability setting 9 11 10 SMS function setting 11 14 11 Set the alarm system 15 12 Function statement 15 16 13...

Страница 3: ...ed in the below places Places are wet or leaking Places with the greenhouse facilities directly affecting Places with the floor tilt uneven or vibration 4 Be in AC220V with the wire holed greater than...

Страница 4: ...coins strat the game 2 Control the left right movement of the key by joystick Press and hold the button to lift the key 3 Aim at the right slot and release the button the key enter into the slot 4 If...

Страница 5: ...k Hanger coordinate Automatically 5 LED 6 Mode 6 as the pic shown above Checking Testing Clear 6 LED 7 Mode 7 as the pic shown above Setting the probability for each line or for each individual 7 LED...

Страница 6: ...oken How to check these permanent data the way is as follows 1 Press the Mode button to select the Mode 8 LED 8 light Shows 8F 2 Press the Enter button appear 8A0000 3 Use the UP and DOWN button to im...

Страница 7: ...3A 1 To 3A 5 as follows 1 3A 1 1 Credit 1 signal 1 Game 2 3A 2 2 Credits 2 signal 1 Game 3 3A 3 3 Credits 3 signal 1 Game 4 3A 4 4 Credits 4 signal 1 Game 5 3A 5 5 Credits 5 signal 1 Game 2 Setting th...

Страница 8: ...puter 2 The format of demo music and game playing music require is MP3 format If 96k frequency can be put into 360 seconds music the time of total music Demo Playing less than 360 seconds 3 Choose the...

Страница 9: ...connect Method of change game music and domo music Press CLEAR button more than 3 second under the setting domo music mode the digital shine is ok 7 SD connect If press ENTER button more than 3 second...

Страница 10: ...inish 15 hole If push key can not go through the hole need to come back to mode 5 to calibration 2 Press TEST button under the mode 6 Pushrod will move from left to right and up and push Test every sw...

Страница 11: ...value profit coin for the unit 2F The winning probability of the second line of lattice 0 5000 20 probability gift value profit coin for the unit 3F The winning probability of the third line of latti...

Страница 12: ...robability gift value profit coin for the unit 4A The 4 hole probability 0 5000 10 probability gift value profit coin for the unit 5A The 5 hole probability 0 5000 10 probability gift value profit coi...

Страница 13: ...e account checking password setting Use UP or DOW button to input the new one to replace the 0003 Under Mode8 the SMS Default Management Password is 0002 Digital tube shows Function Setting Range Fact...

Страница 14: ...manent Data Un prize counter xxxxxx un removable prize Permanent Data Counter credits xxxxxxx total credit show on in the motherboard digital tube Counter prizes xxxxxxx total amount of gift payout sh...

Страница 15: ...ddle line include 5 hooks ratio is 200 0300 means top line include 5 hooks ratio is 300 Notice when setting the ratio 1 the ratio number must 0001 X 5000 2 the ratio number must keep four digits and t...

Страница 16: ...igital tube shows 4bxxxx begin to set the Mobile winning probability setting password use UP or DOW button to input the new password UP button for the tens digits DOWN button for the single digits Pre...

Страница 17: ...message 1 for when the machine get shock the owner can get message 12 Function statement 1 Every gift payout the owner can get a message as A gift cell xx the xx is the hook code Such as the above pic...

Страница 18: ...EST button until the pushrod move 6 when need to take off hook s Take away the hook s reset the coordinate 13 rectify the shooting coordinates point Power off Press and hold the ENTER and TEST button...

Страница 19: ...e is failure of the switch on lower back of the pushrod 8 When Er08 appears on the digital display it shows there is failure of the first sensor of pushrod 9 When Er09 appears on the digital display i...

Страница 20: ...an t return to the left the micro switch fail to close and the organization doesn t move before the failure Pls check the drive around the mobile motor and the corresponding lines When the organizatio...

Страница 21: ...re of the switch on right side of the pushrod mechanism As picture 3 3 Trouble shooting methods When the organization can t return to the right the micro switch fail to close and the organization does...

Страница 22: ...of the Moving Box As picture 6 6 Trouble shooting methods When the fluctuation of the moved motor doesn t work pls check the fluctuation of the moved motor and corresponding lines When the motor can...

Страница 23: ...ck the micro switch and the corresponding lines 8 When Er08 and Er09 appear on the digital display it shows there is failure of the electric eye of push rod detected no signal As picture 8 8 Trouble s...

Страница 24: ...s on the digital display it shows not connect with accounter As picture 9 10 9 10 Trouble shooting Inserted the accounter lines or may be the accounter is broken 10 When Er11 appears on the digital di...

Страница 25: ...ure pls check the motor and corresponding lines When the left and right of the organization can move before failure pls check the electric eye position and baffles position whether appropriate When th...

Отзывы: