background image

English

Français

Esp

añol

Português

1

Important Notes

Codes:

Install in accordance with all local and nation-

al electrical codes.

Power:

The Hybrid Repeater can be powered from

EITHER of two sources:

1. Adapter power. 

Use only the adapter pro-

vided with the Hybrid Repeater (Lutron
model # T120-9DC-3-WH).

Caution -

Using an adapter not rated at the

following specifications could damage the
repeater and possibly overheat the adapter.

• Input: 120 V 60 Hz
• Output: 9 V

300 mA 

NEC Class 2; IEC PELV

2. Link power. 

Use only power supplied via a

HomeWorks

Processor Hybrid Repeater

Link or a 

HomeWorks 

auxiliary power sup-

ply. (See section about the HWI-PS in the

HomeWorks 

Technical Reference Guide or

Application Note HW-104.) Each hybrid
repeater counts as 30 LEDs. 

Note: 

An RF Processor does not supply

power on the Hybrid Repeater Link.

Environment:

Ambient operating temperature: 

32-104°F (0-40°C), 0-90% humidity, non-condensing.
Indoor use only.

Please Read Before Installing

Installation Instructions

Overview

HomeWorks

Hybrid Repeaters add RF capability to

HomeWorks

processors configured with a Hybrid

Repeater Link and provide an additional coverage
area for radio frequency (RF) signals sent between

HomeWorks

RF Dimmers/Switches, RF Keypads, and

RF Processors. Each repeater covers a sphere of
approximately 2500 square feet (232m

2

) of living

space. Up to five (5) repeating devices may be placed
in a 

HomeWorks 

RF system (a 

HomeWorks 

RF

Processor counts as one of the repeating devices).

Hybrid Repeater

HR-REP-120

120 V 60

 

Hz (9 V 300 mA adapter)

HR-REP-120

Hybrid Repeater Wiring:

Hybrid Repeater wiring

must be in a daisy chain configuration. The total
length of wire on the Hybrid Repeater Link may be up
to 1000 feet (305 m), and may contain up to five (5)
Hybrid Repeaters.

Cleaning:

To clean, wipe with a clean damp cloth. 

DO

NOT

use any chemical cleaning solutions.

Device Placement:

HomeWorks 

Hybrid Repeaters

must be located within 30 feet (9 m) of the RF
Dimmers, Switches, and Keypads they are covering.
Hybrid Repeaters must also be within 60 feet (18 m)
of an RF Processor or another repeater when using
the RF Link for repeater-to-repeater or repeater-to-
processor communication. When using the Wired Link
for repeater-to-repeater or repeater-to-processor com-
munication, a total wire length of 1000 feet (305 m)
may be used.

FCC Information

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, persuant to part 15 of the FCC rules.
Operation is subject to the following:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.