CARE AND CLEANING (continued)
5
5. Attach grille (B) by pinching the mounting springs and inserting
them into the narrow rectangular slots in the fan housing (A).
Turn on power source. Test the unit
Housing slots
A
B
Mounting
springs
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
The fan seems louder than it
should.
The CFM is too great for the space.
Be sure the CFM rating on the fan matches the
square footage of your room.
The damper is damaged or not working properly.
Check the damper to ensure it is opening and closing
properly. If the damper has become damaged, please
call Customer Service.
The bend in the duct is too close to the fan discharge
.
Be sure you do not have any sharp bends in the duct
within 18 in. of the fan discharge
.
The fan discharge is reduced to fit a smaller duct.
Use the recommended size ducting to reduce fan
noise.
The fan body is not attached securely.
Be sure the fan is securely attached to the ceiling
joists.
The fan is not clearing
humidity from the room.
There is insufficient airflow intake in the room.
Be sure a door or window is slightly ajar or open to
allow airflow. The fan is not able to draw air out of the
room without enough airflow.
There is insufficient CFM.
NOTE:
Using a tissue is not the correct method for
determining if the fan is operating properly. If the fan
clears steam from the room within approximately 15
minutes of completing your shower, then the fan is
operating properly.
Be sure the CFM rating of the fan matches the
square footage of your room
.
Bluetooth device will not pair
with the fan.
Another device is already paired.
Make sure BLUETOOTH
®
signal is turned off on other
devices.
Switch will not power up.
There is a wiring issue at the switch, or the power is
not turned on at the fuse box or circuit breaker.
Check the wiring diagram on Page 5 and confirm
wiring is correct. Verify the power is turned on.
Switch has power, but the
fan does not.
The grille is not receiving a signal from the switch.
Turn off power. Verify the three connectors from the fan
housing (A) to the grille (B) are connected correctly, then
test. If necessary, disconnect the grille for 5 seconds,
then reconnect the grille and test. Repeat as necessary.
Neutral wire connection from the switch to the fan is
not engaging.
Turn off power. Confirm the house neutral wire is
connected to the switch neutral wire and fan neutral
wire. The switch included with this ventilation fan
requires a dedicated neutral wire connection. If a
neutral line is not present, one must be run by a
qualified electrician.