Specifications 

Eyepiece 

Widefield 10x, large 18 mm diameter lens, with 18 mm exit pupil and fully coated optics. 

Head 

Binocular head, 30° inclined Seidentopf with interpupillary adjustment and dual diopters (MI-
5200BIN).  
Dual-head with one 30° inclined eyepiece and one vertical eyepiece with diopter (MI-
5200DHD). 
Monocular, 30° inclined head rotates 360° (MI-5200STD). 

Nosepiece 

4-hole nosepiece is ball-bearing mounted with positive click stops. 

Objectives 

All plan objectives are DIN achromatic, parfocalled, parcentered, and fully coated. 

 

4x, 0.10 N.A., red ring, 4.5 mm field of view, 40x magnification 

 

10x, 0.25 N.A., yellow ring, 1.8 mm field of view, 100x magnification 

 

40xR, 0.65 N.A., blue ring, 0.45 mm field of view, 400x magnification, retractable 

 

100xR, 1.25 N.A., white ring, 0.18 mm field of view, 1000x magnification, retractable, 
oil immersion  

Focusing 

Separate low position coarse and fine coaxial focusing controls with slip clutch, tension 
adjustment, and precise 0.002 mm fine focus division. 

Focus Rack 

All metal rack-and-pinion focusing with adjustable stage stop. 

Stage 

Acid and chemical resistant 125 x 130 mm metal stage with stage clips and integrated 
mechanical stage. 

Mechanical 
Stage 

Low-position coaxial x-y controls provide precise 70 mm movement on the x-axis and 30 
mm movement on the y-axis.  

Condenser 

Adjustable 1.25 N.A. Abbe condenser with rack-and-pinion focusing and centering controls. 

Diaphragm 

Iris diaphragm with 2 mm to 30 mm diameter opening and swing-out filter holder.  

Illuminator 

Long-life, cool, bright LED illuminator with variable brightness. The illuminator works with 
110-240 volt AC power.  

  

Warranty 

Home  Science  Tools  warrants  this  microscope  to  be  free  from  defects  in  material  and  workmanship  under 
normal  use  and  service  for  the  life  of  the  instrument.  Warranty  does  not  cover  light  bulbs,  batteries,  or 
damage  due to misuse, abuse, alterations, or  accident. Warranty does  not cover lenses that have become 
inoperable due to excessive dirtiness as a result of misuse or lack of normal maintenance.  

 

Any cameras and software supplied with this microscope are under warranty for one year from the purchase 
date.  

Return your microscope freight prepaid for warranty service to Home Science Tools, or the repair facility we 
designate. We will repair or replace your microscope at no charge and return it freight prepaid to you. Please 
call 1-800-860-6272 to arrange warranty service before returning this instrument. Please note that warranties 
apply only to the original purchaser and are not transferable.

 

 
 

Содержание MI-5200BIN

Страница 1: ...0BIN Advanced Binocular Microscope MI 5200DHD Advanced Dual head Microscope MI 5200STD Advanced Microscope 1 800 860 6272 www homesciencetools com Copyright 2012 by Home Training Tools Ltd All rights...

Страница 2: ...enance 6 Adjusting the Stage Stop 6 Changing the Bulb 6 Adjusting Tension 7 Troubleshooting 7 Specifications 8 Warranty 8 General Microscope Care Unpacking The Advanced Microscopes are shipped in a tw...

Страница 3: ...ent damage to the objective or slide The 100x objective is oil immersion this is described on page 5 6 Stage stop Also called a safety rack stop this screw and lock nut located between the stage and t...

Страница 4: ...d extended viewing comfort Using the Binocular Head To best use this feature you must set the interpupillary distance to match the distance between your eyes pupils and adjust the diopters to compensa...

Страница 5: ...focus 10 Adjust the iris diaphragm to reduce light by pulling the lever toward you when facing the stage until the image has clear sharp contrast You need less light on lower power and more light on...

Страница 6: ...cular eyepieces which are described on page 3 Adjustments will vary among different users 1 Have inclined eyepiece user focus the microscope 2 Have the vertical eyepiece user rotate the diopter adjust...

Страница 7: ...er on or rotate illumination intensity control 3 The bulb is burned out 4 The power source outlet is inoperative 5 The incorrect bulb is installed Light flickers 1 The bulb is not properly inserted in...

Страница 8: ...e clips and integrated mechanical stage Mechanical Stage Low position coaxial x y controls provide precise 70 mm movement on the x axis and 30 mm movement on the y axis Condenser Adjustable 1 25 N A A...

Отзывы: