Procedure for the first start
1. Read this instruction manual carefully.
2. Remove information labels from the device.
3. Remove residues of the transport packing.
4.
Fill engine oil into the engine according to the
manual (about 0,5l).
Recommended oil
:
10W40 (-
18°C - 50°C), 5W 40(-40°C - 0°C).
5. Check the engine oil level, or top up.
6. Fill the fuel tank (13-14 l).
7. Check visually the mask air intake cooling to the engine and the
alternator and the surface of the device, make sure that the equipment is
not damaged.
8. Make sure all safety devices and guards are installed and securely
tightened.
9. Check if the powered device is off and unplugged.
Procedure before any further start
1. Check oil level, top up, if the level is below the MIN, do not overfill above
MAX.
2. Check the fuel level, or top up.
3. Check visually the mask air intake cooling to the engine and the
alternator and the surface of the device, make sure that the equipment is
not damaged.
4. Make sure all safety devices and guards are installed and securely
tightened.
5. Check, if the powered device is off and unplugged.
Use of generator to power appliances
1. Start the generator according to the instructions below.
2. Connect the appliances to the plugs, make sure not to exceed the
maximum rated load of the outputs.
3. Make sure that the thermal fuse is ON.
Starting
1. Remove all the loads from the output side.
2. Turn fuel valve to the ON position.
3. Turn the AC circuit breaker to the OFF position.
4. Place the choke control to the CLOSE position. For a warm engine choke
is not required.
5. Move the switch of the ignition switch to the ON position
.