13
3. Pump draining (Only applicable to HME020391N)
- Remove the continuous drain hose from the unit.
Replace the plastic cover of the continuous drain hose
outlet tightly.
- Attach the pump drain hose (Outer diameter: 1/4”;
length: 16.4 ft) to the pump drain hose outlet. The
insert depth should not be less than 0.59 inch.
Lead the drain hose to the floor drain or a suitable
drainage facility.
Reinstall the
plastic cover
Pump drain hose outlet
(Only applicable to
HME020391N)
Pump drain hose
- Press
Pump
button to pump the water. When the
bucket is full, the pump will start to work. It is normal
that the pump makes loud noises at first 3~5 minutes
of work.
REMOVING THE COLLECTED WATER (CONT.)
Note:
- Make sure the connection is tight and there is
no leaking.
- If the pump hose drops when removing the
bucket, you must install the pump hose to the
unit before replacing the bucket into the unit.
- The maximum pumping elevation is 16.4 ft.
Note:
Do not use the pump when the outdoor
temperature is equal to or less than 32°F (0°C),
otherwise the water will freeze, causing the water
hose to block up and the dehumidifier may be
damaged.
Operation
Pump hose drops
Reinstall pump