14
15
BATTERY TEST:
• Switch off mains power. The Green LED on the smoke alarm will be OFF.
• Test alarm by pressing on the Test Button for a few seconds.This should sound the alarm.
• If the battery module has a fault, the alarm will chirp every 40 seconds.
• Watch the Red LED for about 40 seconds. It should flash at least once.
• Switch on mains power only when smoke alarm passes the above tests. The Green LED on the
smoke alarm will come ON.
NOTE: WEEKLY TESTING IS RECOMMENDED!
INSTALLER PLEASE NOTE:
• Before you connect the mains power, check wiring polarity.
• please check battery is correctly connected and fully change over 8.0 Volts.
• If the alarm ‘chirps’ again, press the Test button to check the battery condition.
• If ‘chirps’ persists, replace smoke alarm and return to your supplier for replacement.
Please Note: When TEST button is pressed after testing mode, the smoke alarm will
automatically enter HUSH mode. Smoke alarm will be desensitized for 10 minutes.
Smoke testers may not be effective during hush mode.