background image

19

RISK CATEGORY INDEX

This monitor comes equipped with a Risk Category 

Index that automatically compares each reading 

to defined levels established by the U.S. National 

Institutes of Health’s (NIH) National Heart Lung and 

Blood Institute as described earlier in this manual, 

and provides a helpful cue if your reading falls into 

one of the stages that could potentially indicate 

increased risk. No cue is given if the reading falls in 

the normal range as defined by NIH. Please note that 

cues provided by this monitor are only intended to 

assist you in using this table. The table and cues are 

only provided for convenience to help you understand 

your non-invasive blood pressure reading as it relates 

to the NIH information. They are not a substitute for a 

medical examination by your physician. It is important 

for you to consult with your physician regularly. Your 

physician will tell you your normal blood pressure 

range as well as the point at which you may actually 

be considered to be at risk.

(No Symbol)

20

IRREGULAR HEARTBEAT DETECTOR (IHB)

The appearance of the 

 

icon indicates that a pulse 

irregularity consistent with 

an irregular heartbeat was 

detected during measurement. 

Usually this is not a cause 

for concern. However, if the 

symbol appears often, we 

recommend you seek medical 

advice. Please note that the device does not replace a 

cardiac examination, but serves to detect pulse irregularities 

at an early stage. 

Movement, shaking or talking during the measurement can 

result in pulse irregularities that may cause the appearance of 

this icon. Therefore, it is of great importance to not move or 

talk during measurement.

To determine the presence of an irregular heartbeat, the 

average of the heartbeat intervals is calculated with the first 

3 normal effective heartbeat values. It is important to note 

that the average is not a strict mathematical averaging of 

all recorded intervals. At least 3 beats with 25% or greater 

difference from the average heartbeat interval will generate 

the 

 icon on the screen. 

IMPORTANT INFORMATION:

This blood pressure monitor is not designed for use by 

people with arrhythmias nor for diagnosing or treating an 

arrhythmia problem. As a safeguard, we recommend that if 

you have arrhythmias such as atrial or ventricular premature 

beats and atrial fibrillation or any other special conditions you 

should check with your physician before using your blood 

pressure monitor.

Irregular 
Heartbeat 
Detector

Содержание Walgreens WGNBPW-910

Страница 1: ...AUTOMATIC WRIST Blood Pressure Monitor 5 Year Limited Warranty WGNBPW 910 Ver A El manual en espa ol empieza en la p gina 34...

Страница 2: ...netic Compatibility EMC 26 Troubleshooting 28 Specifications 29 5 Year Limited Warranty 31 TABLE OF CONTENTS INTRODUCTORY INFORMATION Important Product Notices and Safety Instructions 3 About Blood Pr...

Страница 3: ...s hemorrhage or temporary numbness to your wrist In general these symptoms should not last long However if you do not recover in time please seek advice from a medical professional Consult your physic...

Страница 4: ...Hypertension refers to blood pressure that rises above its usual level when measured in a clinical setting such as a doctor s office BLOOD PRESSURE STANDARD The table below contains defined levels fo...

Страница 5: ...through your artery Once the measurement is complete the cuff will automatically deflate Please note that any muscle movement during inflation will cause measurement error When measurement is complete...

Страница 6: ...nformation Measurement Error Wrap the cuff correctly and keep wrist steady during measurement Measure again Air Circuit Abnormality Measure again Pressure Exceeding 300 mmHg Switch the unit off to cle...

Страница 7: ...teries if The weak battery symbol appears on the display Nothing appears on the display when the power is switched on Note Date and time will need to be reset if batteries are removed or replaced Repl...

Страница 8: ...jewelry etc prior to attaching the wrist monitor Clothing sleeves should be rolled up and the cuff should be wrapped around bare skin for correct measurements 2 Apply cuff to left wrist with palm fac...

Страница 9: ...od pressure changes with every heartbeat and is in constant fluctuation throughout the day Blood pressure measurement can be affected by the position of the user his or her physiologic condition and o...

Страница 10: ...flate the cuff to begin measurement START STOP 3 When the measurement is completed the cuff will deflate entirely and systolic pressure diastolic pressure and pulse will be shown simultaneously on the...

Страница 11: ...nt with an irregular heartbeat was detected during measurement Usually this is not a cause for concern However if the symbol appears often we recommend you seek medical advice Please note that the dev...

Страница 12: ...rements at the same time each day and use the same wrist for consistency Users should wait a minimum of 5 minutes before taking additional measurements More time may be necessary depending upon your p...

Страница 13: ...ms with this device please contact HoMedics Consumer Relations contact information on warranty page Do not immerse the unit in water as this will result in damage to the unit 23 24 Do not subject the...

Страница 14: ...ctromagnetic environments listed below and should only be used in such environments Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 RF energy is used only...

Страница 15: ...tion from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broa...

Страница 16: ...5 93 RH Storage Transportation Environment Temperature 13 F 158 F 25 C 70 C Humidity Less than 93 RH SPECIFICATIONS 30 Weight 0 20 lbs 91 7 g without batteries Wrist Circumference 5 3 7 7 13 5cm 19 5c...

Страница 17: ...product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for w...

Страница 18: ...MONITOR AUTOM TICO De presi n arterial para el brazo Garant a limitada por 5 a os WGNBPW 910 Ver A...

Страница 19: ...i n de fecha y hora 47 Aplicaci n del brazalete 48 36 Postura correcta para la medici n 49 Procedimiento de medici n 50 ndice de categor a de riesgo 53 Detector de latidos card acos irregulares IHB 54...

Страница 20: ...riosclerosis grave enfermedad renal grave o enfermedad vascular que pueda afectar la circulaci n 38 El uso excesivo puede provocar interferencia del flujo sangu neo lo que probablemente produzca sensa...

Страница 21: ...n los Pulmones y la Sangre National Heart Lung and Blood Institute de los Institutos Nacionales de la Salud National Institutes of Health NIH de los Estados Unidos http www nhlbi nih gov health dci D...

Страница 22: ...la que se encuentran sus resultados de medici n en la tabla del Instituto Nacional del Coraz n los Pulmones y la Sangre de los NIH y brinda una gu a si su lectura entra en una de las etapas que podr...

Страница 23: ...r m s informaci n Error de medici n vuelva a colocarse el brazalete correctamente y mantenga la mu eca quieta durante la medici n Repita la medici n Irregularidad en el circuito de aire repita la medi...

Страница 24: ...uevamente en su lugar 1 2 3 4 46 Reemplace las bater as si El s mbolo de bater a baja aparece en la pantalla No aparece nada en la pantalla cuando enciende el dispositivo Nota Si se extraen o sustituy...

Страница 25: ...oj las alhajas que tenga en la mu eca etc antes de colocar el monitor para la mu eca Deber remangarse si tiene mangas largas y deber colocarse el brazalete sobre la piel desnuda para obtener una medic...

Страница 26: ...arterial cambia con cada latido card aco y est en constante fluctuaci n durante todo el d a La medici n de la presi n arterial puede verse afectada por la posici n del usuario sus condiciones fisiol g...

Страница 27: ...amente para comenzar la medici n START STOP 3 Cuando haya finalizado la medici n el brazalete se desinflar por completo y se mostrar n las lecturas de presi n sist lica presi n diast lica y pulso simu...

Страница 28: ...arece un cono que lo indica Generalmente esto no es causa de preocupaci n Sin embargo si el s mbolo aparece con frecuencia recomendamos que busque asesoramiento m dico Tenga en cuenta que este disposi...

Страница 29: ...d as a la misma hora y en la misma mu eca para establecer una coherencia Los usuarios deber n esperar un m nimo de 5 minutos antes de tomar otras mediciones Dependiendo de su fisiolog a es posible que...

Страница 30: ...r del mismo Si tiene problemas con este dispositivo comun quese con Relaciones con el consumidor de HoMedics encontrar la informaci n de contacto en la p gina de la garant a No sumerja la unidad en ag...

Страница 31: ...un tomacorriente de un circuito diferente al que est conectado el receptor Consulte con el distribuidor o con un t cnico experto en radio televisi n para obtener ayuda COMPATIBILIDAD ELECTROMAGN TICA...

Страница 32: ...3 3 Vrms 150 kHz a 80 MHz 3 V m 80 MHz a 2 5 GHz No se aplica 10 V m No se deben acercar equipos de comunicaci n por RF port tiles o m viles a ninguna pieza del dispositivo incluidos los cables a una...

Страница 33: ...nte la medici n Repita la medici n Sacudi la mu eca con el brazalete colocado Aparece el s mbolo de error E1 en la pantalla Irregularidad en el circuito de aire Repita la medici n Aparece el s mbolo d...

Страница 34: ...8 10 Esta garant a se extiende nicamente a consumidores y no a distribuidores Para obtener servicio de garant a en su producto HoMedics p ngase en con tacto con un Representante de Relaciones con el...

Страница 35: ...TO DISPONIBLES PARA LOS MATERIALES DEFECTUOSOS HOMEDICS SE RESERVA EL DERECHO DE REALIZAR SUSTITUCIONES EN VEZ DE REPARAR O CAMBIAR Esta garant a no se extiende a la compra de productos abiertos usado...

Отзывы: