Level
6
5
Screws
Assembly
Screw
Setting The Zero Point and Balance
Before using the scale for the first time or when the scale has been moved to
another place, you must set the zero point and balance the scale before
weighing yourself.
Zero Point
1. With nothing on the
PLATFORM
, adjust
POINTER
to
ZERO
using
ADJUSTING KNOB
found under
DIAL
, on the unit’s back side.
Balance
1. Place the scale on a flat, firm surface
2. Turn 6
LEVELING FEET
until the bubble inside
LEVEL
is directly in the
middle of the circle
Adjusting
Knob
Leveling
Foot
Locking
Dial
Platform Top
Leveling Feet
Pothook
Long Arm
Connection
Plate
3. Use
SCREW DRIVER
to hook
POTHOOK
into the hole of
LONG ARM
CONNECTION PLATE
4. Use
ALLEN KEY
to remove the pre-set
ASSEMBLY SCREW
(located on
the bottom of the base) to release
LONG ARM CONNECTION PLATE
into place
5. Use
SCREW DRIVER
to attach
POLE
to
BASE
by inserting and turning the
2 screws tightly
6. Slide
POLE COVER
down
SC-630-A.qxd 10/6/06 3:49 PM Page 5