background image

6

7

HOW TO OPERATE

1. Press and hold + 

button for 3 seconds to power the unit ON and listen for the 

beep. 

Note: The unit will not operate if it is not in contact with your skin.

2. Press + 

button again to activate device. Continue to press the + button until you 

feel the sensation of the impulses.

3. Use +/- 

button to adjust intensity level, note there are 15 levels. 

4. The device automatically powers off after 20 minutes, or press and hold - 

button 

for 3 seconds to power OFF.

Note:

•  Battery will need to be replaced if the device no longer makes a beep sound 

or sends any electric impulses. Please check the troubleshooting section for 

additional issues with beeping. 

•  Device only works when in contact with the skin. When the device is not in contact 

with the skin, the device will not activate the impulses.

•  After use, always place the device into the provided carry case protecting the gel 

pad after use.

•  Smart Contact Detection automatically sends audible alerts when the gel pads are 

not securely fixed to the skin.

•  When power is on, intensity level is set to 0 for safety purposes. Press the  

+ button again to activate and increase intensity.

Press 3 sec to power ON; 

increase intensity

Press 3 sec to power OFF; 

decrease intensity

MAINTENANCE

Storage of the device:
(1)  Keep the device away from children.
(2)  Remove the battery if the unit will not be used for more than 10 days.
(3)  Place the device into the protective carry case to protect the adhesive gel pads 

and device.

(4)  Do not store the unit under high temperature, high humidity, direct sunlight, 

exposed environment or where there is a lot of dust or corrosive gas.

Care for Device
(1) To avoid damage to the device:

 - When removing the device from the carry case pull out gentle and slow.
 - Do NOT twist the device.
 - Do NOT pull on the device pads strongly, or pull outward from the device center.
 - Do NOT push or pull on the device center, this can deform the device causing 

operation issues.

 - Do NOT disassemble any part of the device.

Care for gel pads:
(1)  If the adhesive gel pads get dirty or less sticky you can prolong the life for 

additional uses by cleaning it. With a drop of water on your finger, rub the water 

over the surface of the gel and allow it to dry.

(2)  Always store the gel pads in the protective case after use. Do not store it in other 

areas, or adhere the gel to a surface other than your skin or the inside of the 

protective case as this can damage the gel and reduce the life of it.

(3)  Be sure the skin is clean before the gel pads are placed on the body.
(4)  Always store in a cool, airy area away from direct sun light.

Replacing the gel pads:
(1)  To remove the gel pad carefully roll the gel upwards with your fingers until the 

entire pad has lifted off. Note: Do not use fingernails or tools as they can damage 

the unit.

(2)  Repeat on other side.
(3)  Clean the device with a drop of water on your finger to remove left over residue. 

Allow to dry. 

(4)  Place new pads onto the unit following steps 5-8 in the Battery and Gel Pad 

Assembly section.

Содержание Rapid+Relief HW-P105

Страница 1: ...please visit www rapidreliefpad com HW P105 Ver C P l e ase Take A Moment N o w Register Your Product At www homedics com register Your valuable input regarding this product will help us create the p...

Страница 2: ...o the heart in susceptible individuals Device is ineffective for pain of central origin including headaches This device has no curative value it is a symptomatic treatment and as such suppresses the s...

Страница 3: ...r normal household and work activities WHAT IS RAPID RELIEF Rapid Relief is a TENS device TENS stands for Transcutaneous Electrical Nerve Stimulation The device emits controlled micro electric current...

Страница 4: ...rotective carry case to protect the adhesive gel pads and device 4 Do not store the unit under high temperature high humidity direct sunlight exposed environment or where there is a lot of dust or cor...

Страница 5: ...nnection with the contact points try again Battery may no longer be good Replace the battery and try again Gel pads are no longer sticking to the body Clean the gel pad with a drop of water on your fi...

Страница 6: ...The auto off program is engaged and the unit is powering off Beep Signal Description Chart cont d Power Mode Operation Types of Beep Signal Signal Description In Use Short press of the button Single s...

Страница 7: ...urchased A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of...

Страница 8: ...o aho r a Registre su producto en www homedics com register Su valioso aporte sobre este producto nos ayudar a crear los productos que desee en el futuro Para obtener m s informaci n por favor visite...

Страница 9: ...ormal La colocaci n de las almohadillas de gel y las configuraciones de estimulaci n deben basarse en la gu a del Manual de instrucciones Actualmente se desconocen los efectos a largo plazo de la esti...

Страница 10: ...jemplo flebitis tromboflebitis vena varicosa etc No se debe aplicar el dispositivo sobre o cerca de lesiones cancerosas Si tiene afecciones de la piel en la zona lumbar que incluyen Piel gravemente o...

Страница 11: ...a la unidad no funcionar si no entra en contacto con la piel 2 Presione el bot n nuevamente para activar el dispositivo Contin e presionando el bot n hasta que perciba la sensaci n de los impulsos 3 U...

Страница 12: ...e siempre las almohadillas de gel en un lugar fresco y aireado alejado de la luz solar directa Reemplazo de las almohadillas de gel 1 Para extraer la almohadilla de gel enr llela cuidadosamente con lo...

Страница 13: ...Deje de tratar esa zona de inmediato espere hasta que la piel vuelva a su estado sano Si la irritaci n contin a con sulte a un dermat logo La intensidad comienza a disminuir de repente Reemplace la b...

Страница 14: ...a se al En uso Presione brevemente el bot n Un pitido corto La funci n de intensidad ajustable ha aumentado 1 nivel Presione brevemente el bot n Un pitido corto La funci n de intensidad ajustable ha d...

Страница 15: ...LA GARANT A QUE SE PROPORCIONA EN EL PRESENTE DOCUMENTO SER LA GARANT A NICA Y EXCLUSIVA NO EXISTIR N OTRAS GARANT AS EXPRESAS NI IMPL CITAS QUE INCLUYEN CUALQUIER GARANT A IMPL CITA DE COMERCIALIZAC...

Отзывы: