How to use the CLEAN Function:

 If you wish to change the type of soap in the Dispenser, you may use 

the CLEAN function to empty and clean the unit. Open the Battery/Control Compartment door (Figure 2).  
Press the CLEAN button and the unit will enter the auto cleaning mode. The motor will turn on and 
pump for 30 seconds. During this period, you can press the CLEAN button again to abort the cleaning 
function (motor will turn off). Repeat until there is no more soap in the reservoir. To thoroughly flush out 
the unit, you should add water to the reservoir and repeat the cleaning process. 

Note:

 Hold device over a sink or dish when running the Clean function, to prevent soap from spilling 

onto counter.

IMPORTANT:

1.  The Motion Detector that activates dispensing uses a sensitive infrared sensor. To avoid accidental  
  dispensing of soap, please do not place the Soap Dispenser in direct sunlight.
2.  After a period of inactivity, the soap inside Soap Dispenser may become dry and clog the line.  
  Should this occur, simply use a toothpick or water to remove the obstruction. 
3.  The only part of the Soap Dispenser designed to be wet is the liquid reservoir and spout. Do not  
  immerse the Soap Dispenser in water as the product will be damaged.
4.  Run the CLEAN Function to flush the liquid/soap reservoir with water and remove batteries from the  
  battery compartment whenever the Soap Dispenser is to be left unused for a long period of time.
5.  To clean the unit, use a soft damp cloth. Do not clean with a abrasive materials or corrosive  
  substances.
6.  The device is not designed to be held or tipped upside down when there is soap in the Reservoir.  
  Use caution to maintain the device on a level surface at all times.
7.  Make sure your child understands that liquid soap solution is not for drinking and that it should be  
  kept away from the eyes.

Trouble Shooting:

No Soap Dispensed; Motor Does Not Run

1.  Ensure that Soap Dispenser is turned on. Press and hold the POWER button for 3 seconds to turn  
  off. Press the POWER button once to turn ON.
2.  Make sure hands are placed directly between the Motion Sensor and Spout.
3.  Ensure that unit is not placed in bright sunlight, which will interfere with Motion Sensor operation.
4.  Check that batteries are installed with correct polarity (+/–) and are not dead.

No Soap Dispensed; Motor Runs

1.  During start-up you may need to activate the Motion Sensor several times to “prime” the pump to  
  begin dispensing soap.
2.  The soap reservoir should be at least ¼ FULL.
3.  Make sure that no dried soap is clogging the spout or pump tubing. Use a toothpick to clean the  
  spout if necessary.

No Audio/Song

1.  If unit dispenses (motor runs) but does not play music, the SONG button has been turned OFF.   
  Make sure your hands are dry before opening the battery compartment. Open the battery  
  compartment and press the SONG button once to activate the SONG mode.
2.  If unit does not dispense (motor does not run) or play audio, check batteries for proper positioning  
  and/or replacement.

Battery Precautions:

1.  Use AA alkaline batteries only. Do not use rechargeable batteries.

2.  Replace all batteries at the same time.

3.  Clean the battery contacts and the contacts of the device prior to battery installation with a dry cloth.

4.  Ensure the batteries are installed correctly with regard to polarity (+/–).

5.  Remove batteries from the unit when it is not to be used for an extended period of time.

6.  Remove depleted batteries from the unit promptly. Dispose of used batteries safely. Keep all  

  batteries away from children. Batteries are small objects and could be ingested. If swallowed,  

  contact a physician at once. Do not open batteries or dispose of in fire. Do not mix the new and  

  used batteries.

Note:

 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired operation.

Note:

 The manufacturer is not responsible for any radio or TV interference caused by unauthorized 

modifications to this equipment. Such modifications could void the user authority to operate the 

equipment.

Note:

 This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses, and can radiate 

radio frequency energy and, if not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, the user is encouraged to try 

to correct the interference by one or more of the following measures:
•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is  

  connected.
•  Consult the dealer or an experienced radio/TV technician for help.

Содержание MYB-W10

Страница 1: ...ó el producto Un producto que requiera modificaciones o adaptación para habilitar su funcionamien to en cualquier país que no sea aquél para el que fue diseñado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI...

Страница 2: ...or 12 seconds while the unit is in Setup Mode During this period the Motion Sensor and motor will not function This will allow enough time to close the Battery Control Compartment door and position the unit without triggering the Motion Sensor 3 Attach the Drip Tray by placing as shown below Magnets help to secure in position 4 Place your hand under the spout to activate the Motion Sensor The Soap...

Страница 3: ... clogging the spout or pump tubing Use a toothpick to clean the spout if necessary No Audio Song 1 If unit dispenses motor runs but does not play music the SONG button has been turned OFF Make sure your hands are dry before opening the battery compartment Open the battery compartment and press the SONG button once to activate the SONG mode 2 If unit does not dispense motor does not run or play aud...

Страница 4: ... purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE ...

Страница 5: ...en el modo Configuración Setup Durante este período el sensor de movimiento y el motor no funcionarán Esto permitirá el tiempo suficiente para cerrar la puerta del compartimiento de las pilas y control y colocar la unidad sin activar el sensor de movimiento 3 Adose la bandeja para el goteo según se muestra a continuación Los imanes ayudan a mantener la posición 4 Coloque su mano bajo el pico para ...

Страница 6: ... de su capacidad 3 Asegúrese de que no haya jabón seco obstruyendo el pico o la tubería de bombeo Use un palillo para limpiar el pico si fuera necesario No hay audio no se escucha la canción 1 Si la unidad dispensa el motor funciona pero no hay música el botón de canción SONG ha sido apagado OFF Asegúrese de que sus manos estén secas antes de abrir el compartimiento de las pilas Abra el compartimi...