background image

BEFORE YOU BEGIN:

1.

IMPORTANT:

Insert batteries into the home receiver unit first, then the

remote sensor.

2. Place the home unit as close as possible to the remote unit.  This will

help with synchronization between the remote sensor and the home unit.

3.

REMEMBER:

Once you are ready to position your remote sensor and

home unit, ensure that the distance is not outside the effective trans-
mission range (100 feet).  Some building materials and location of the
home unit or remote sensor can affect transmission quality and range.
Try various locations for best results.

BATTERY INSTALLATION

Home Receiver:

Lift off the battery cover on the back of the unit.  Install 2 “AA” alkaline
batteries included according to the polarity indicated. Close the battery
cover.

Remote Sensor:

Remove the attached bracket stand.  Loosen the 2 screws securing the
battery cover with a small screwdriver and remove.  Insert 2 “AA” alkaline 
batteries included according to the polarity direction indicated.  Depress the
C/F button to select either Centigrade or Fahrenheit temperature reading.
Ensure the black gasket is properly seated in the housing and then replace
the cover. Tighten the 2 screws to secure.

NOTE: There are no consumer serviceable parts.  

(See Warranty section for contact information.)

GETTING STARTED

SETTING UP THE WIRELESS THERMOMETER

If you encounter any difficulties in setting up your wireless thermometer
system, please contact Consumer Relations.

• For the first installation, always insert batteries into the home unit 

FIRST

and then the remote sensor(s). (See BATTERY INSTALLATION section)

• Your new RF Thermometer is built with security code technology, the

home unit will learn the code of the first remote sensor and log it in as
channel 1.  Channel 2 and Channel 3 will be registered in the same way if
additional sensors are used.  This unit can monitor up to 3 separate
sensors.

• Once a channel is registered, it will not accept any new sensors. However,

registered channels can be erased by removing the batteries in the
remote sensor or the home unit. 

When replacing batteries for the remote sensor

- Remember to clear the

corresponding channel of the home unit by removing the batteries.  –OR–
Select the respective channel of the sensor by pressing the CHANNEL
button.  Hold the CHANNEL button for 3 seconds to clear the registration.

• Press the Tx button on the back of remote sensor to verify the RF reception.
• It is recommended to test the units next to each other to ensure that both

the remote sensor and home receiver are properly synchronized.

NOTE: Keep the remote sensor out of direct sunlight and rain.  Do not
mount on metal surface.

SETTING UP THE BAROMETER

When powering up, the pressure/altitude display will show “Auto” and
“Meter” for 60 seconds.  It will automatically calculate and display the current
altitude above sea level.  Please compare the displayed altitude value (in
meters) against the exact altitude you obtain from a local authority.  Enter
your value if the displayed value is not exactly correct.  
To reset or recalibrate, please follow these steps:
1. Hold “

Pressure/Altitude

” key for 3 seconds.

2. Select Meter or Feet by pressing the “

Pressure/Altitude

” button.  Press

HIST

” to confirm.

3. Press “

Pressure/Altitude

” and “ 

P/A- 

” to enter the altitude value (-100 m

to 2500 m).

4. Press “

HIST

” to confirm and exit.

2

3

DWS-400-IB SPENG-REV  11/22/04  3:21 PM  Page 3

Содержание EnviraStation DWS-400

Страница 1: ...e ciales Todas las garantías implícitas incluyendo entre otras aquellas garantías implícitas de idoneidad y comerciabilidad están limitadas a la duración total de dos años a partir de la fecha de compra original Para obtener un servicio cubierto por la garantía para su producto HoMedics puede entregar la unidad personalmente o enviarla por correo junto con su recibo de compra fechado como prueba d...

Страница 2: ...tion Your new RF Thermometer is built with security code technology the home unit will learn the code of the first remote sensor and log it in as channel 1 Channel 2 and Channel 3 will be registered in the same way if additional sensors are used This unit can monitor up to 3 separate sensors Once a channel is registered it will not accept any new sensors However registered channels can be erased b...

Страница 3: ... memory record press CLEAR AL button while the respective values are displayed on screen To select between mb hPa and inHg hold P A key for 3 seconds To view air pressure for the past 12 hours press the HIST button to scroll through the hourly readings The respective values can only be available after the barometer has recorded the pressure data in the past 12 hours Push any other button to cancel...

Страница 4: ... alarm will sound Press any button on the home receiver to acknowledge and stop the alarm 6 WEATHER FORECAST WITH STORM ALERT The built in sensor will read the atmospheric pressure and calculate the weather conditions of the next 12 hours These conditions will be displayed as Sunny Partial Sunny Cloudy Rainy Stormy Icy at the top of the LCD display LOW BATTERY INDICATION Low battery indication is ...

Страница 5: ...recommend using only alkaline batteries for replacements 8 Where can I mount the remote sensor To get accurate readings and to prolong the life of your sensor we recommend that you mount it out of direct sunlight and rain Fog and mist will not affect the sensor but large volumes of soaking rain may To guard against this we recommend that you mount it under the eve of your house your garage or any ...

Страница 6: ...to select F C temperature humidity and air pressure CHANNEL Select Channel 1 2 3 Delete current channel auto scroll SNOOZE Backlight on 5 seconds LIGHT trigger snooze alarm HISTORY View barometric readings for last 12 hours P A View pressure or altitude Set altitude P A Step forward for altitude Fast advance P A Step backward for altitude Fast backward Select hPa inHg 10 11 Weather Forecast With T...

Страница 7: ...t not limited to those implied warranties of fitness and merchantability are limited in the total duration of two years from the original purchase date To obtain warranty service on your HoMedics product either hand deliver or mail the unit and your dated sales receipt as proof of purchase postpaid along with check or money order in the amount of 5 00 payable to HoMedics to cover handling Upon rec...

Страница 8: ...a sección de INSTALACIÓN DE LAS BATERÍAS Su nuevo termómetro RF está construido con tecnología de códigos de seguridad la unidad doméstica captará el código del primer sensor exterior y lo registrará en él como canal 1 Los canales 2 y 3 se registrarán del mismo modo en caso de usar sensores adicionales Esta unidad puede monitorear hasta 3 sensores separados Una vez registrado un canal éste no acep...

Страница 9: ...cancelar el récord en memoria oprima CLEAR AL cancelar alarma mientras la pantalla indica los respectivos valores 4 Oprima el botón HIST para confirmar su selección y salir Para seleccionar entre mb hPa y inHg sostenga la tecla P A por 3 segundos Para ver la presión de aire de las últimas 12 horas presione el botón HIST para recorrer las lecturas de cada hora Los valores respectivos sólo pueden es...

Страница 10: ... para las próximas 24 horas Estas condiciones aparecen como Asoleado Parcialmente asoleado Anublado Lluvioso Tempestad Hielo en la parte superior de la pantalla LCD 18 INDICADOR DE BATERÍA BAJA La indicación de batería baja está disponible en el receptor doméstico y en el sensor remoto Cambie las baterías y siga el procedimiento de inicialización como se indica en este manual de instrucciones INST...

Страница 11: ...mendamos el montaje debajo del voladizo de su casa del garaje o cualquier otro lugar adecuado que lo abrigue de la luz solar directa y de la lluvia Las modificaciones no autorizadas por el fabricante pueden invalidar el derecho del 20 usuario a operar este dispositivo Atención Este equipo ha sido ensayado y probado y se ha comprobado que cumple con los límites de los dispositivos digitales de la C...

Страница 12: ...la pantalla por 5 segundos LIGHT Activa la alarma repetida HISTORY Muestra las lecturas barométricas de las últimas 12 horas P A Muestra la presión o la altitud Avance rápido P A Añade una unidad de altitud Avance rápido P A Sustrae una unidad de altitud Devolución rápida Selección de hPa inHg 22 23 Previsión del tiempo con Indicador de ten dencia Temperatura exterior Previsión del tiempo con Indi...

Отзывы: