Turning the Unit On

•  Take the air cleaner out of the box and remove the clear protective plastic bag.
•  Place the air cleaner on a firm level surface.
•  Before turning the air cleaner ON, you need to confirm that the filters are firmly in  

  place and did not become loose during shipping.  

1. To check filters, open the rear grill by  

  gently pushing down on the release  

  tab on the top of the rear grill. Fig. 1

2. Open the plate outward until the tabs  

  at the bottom of the grill plate easily  

  slide away from the unit. Fig. 2

3. The HEPA filters will be resting inside  

  the unit. Make sure that the filters are  

  firmly seated inside of the unit. Fig. 3

 
4. Place the tabs at the bottom of the  

  grill plate into the base of the unit.  

  Gently push the grill plate back into  

  place until you hear a click sound  

  indicating that the grill is firmly  

  latched. Fig. 4
  Connect the power cord into a    
  standard AC outlet.

NOTE: Unit will not operate unless filters and grill are properly installed.

Fig. 1

Fig. 2

Fig. 3

NOTE: This appliance has a polarized plug (one blade is wider than
the other). To reduce the risk of shock, this plug is intended to fit only
one way in a polarized outlet. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature. To do so could result in
an electric shock hazard.

Control Panel

Fan Speed

UV-C Bulb

On/Off

Power On/Off

UV-C Bulb Reset

Timer

Oscillation

On/Off

Clean Filter 

Reset

Fig. 4

Содержание AR-45

Страница 1: ...namiento en cualquier país que no sea aquél para el que fue diseñado fabricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGAC...

Страница 2: ...r children or invalids and whenever the air cleaner is left operating and unattended Always unplug the air cleaner when not in use Do not operate the air cleaner with a damaged cord or plug or after the air cleaner malfunctions has been dropped or damaged in any manner Return to HoMedics Consumer Relations for examination electrical or mechanical adjustment or repair This air cleaner is not intend...

Страница 3: ...roduct earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model s CADR for Dust and the electrical energy it consumes or CADR Watt Control Panel Main Unit UV C Lig...

Страница 4: ... Fig 3 4 Place the tabs at the bottom of the grill plate into the base of the unit Gently push the grill plate back into place until you hear a click sound indicating that the grill is firmly latched Fig 4 Connect the power cord into a standard AC outlet NOTE Unit will not operate unless filters and grill are properly installed Fig 1 Fig 2 Fig 3 NOTE This appliance has a polarized plug one blade i...

Страница 5: ...e UV C button on the control panel To turn the UV C bulb off press the button again 5 Clean Filter Indicator The air cleaner is equipped with a CLEAN FILTER indicator to let you know when it is time to clean the HEPA filters about every 480 hours of use When the HEPA filters are ready to be cleaned the CLEAN FILTER indicator will light up on the control panel If the air cleaner is used daily we re...

Страница 6: ... detach the metal UV C bulb cover 5 Grasp the UV C bulb firmly and pull it from the bulb socket 6 Replace the new UV C bulb and push it into the bulb socket 7 Replace the metal UV C bulb cover 8 Replace the rear grill NOTE UV C bulb contains Mercury Hg Dispose of according to Local State and Federal Law www lamprecycle org Cleaning the HEPA Filters Make sure that the air cleaner is turned OFF and ...

Страница 7: ...eaning and Maintenance For best performance we recommend Vacuum the HEPA filters using the brush attachment of your vacuum cleaner once a month NEVER use water or any household cleaners or detergents to clean the HEPA filters Clean off the outside of the unit with a dry cloth once a month NEVER use water wax polish or any chemical solution to clean the outside of the unit Clean off the grill plate...

Страница 8: ...her country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE P...

Страница 9: ...or de aire cuando no lo esté usando No haga funcionar el limpiador de aire con un cable o un enchufe dañado o después de que limpiador de aire no funcione adecuadamente se haya caído o dañado de cualquier manera Devuelva a Atención al consumidor de HoMedics para que lo examinen lo ajusten eléctrica o mecánicamente o lo reparen Este limpiador de aire no está diseñado para usarse en baños áreas de l...

Страница 10: ...ón ENERGY STAR cumpliendo estrictas pautas de eficiencia energética establecidas por US EPA US EPA no respalda ninguna declaración del fabricante sobre aire interior más saludable a partir del uso de este producto La eficiencia energética de este modelo calificado según ENERGY STAR se mide basándose en una relación entre CADR tasa de suministro de aire limpio para el polvo y la energía eléctrica q...

Страница 11: ...n el envío 1 Para revisar los filtros abra la rejilla trasera empujando suavemente hacia abajo la pestaña de liberación que se encuentra en la parte superior de esa rejilla Fig 1 2 Abra hacia afuera la bandeja hasta que las pestañas de la base de la rejilla se deslicen fácilmente fuera de la unidad Fig 2 3 Los filtros HEPA estará apoyado dentro de la unidad Asegúrese de que los filtros se encuentr...

Страница 12: ...a configuración HIGH alta Para disminuir la velocidad del ventilador presione el botón SPEED menos velocidad hasta lograr la configuración deseada La configuración de velocidad del ventilador se indica en el anillo iluminado que se encuentra alrededor del ícono del ventilador Para apagar el limpiador de aire simplemente presione el botón ON OFF encendido apagado en el panel de control 2 Temporizad...

Страница 13: ...etal de la bombilla UV C 5 Tome con firmeza la bombilla UV C y retírela del portalámparas 6 Coloque la nueva bombilla UV C y empújela dentro del portalámparas 7 Vuelva a colocar la cubierta de metal de la bombilla UV C 8 Vuelva a colocar la rejilla trasera NOTA la bombilla UV C contiene mercurio Hg Deseche de acuerdo con las leyes locales estatales y federales www lamprecycle org Limpieza de los f...

Страница 14: ...problemas Limpieza y mantenimiento Para un mejor desempeño recomendamos Aspire los filtros HEPA usando el accesorio de cepillo de su aspiradora una vez al mes NUNCA use agua ni ningún otro limpiador o detergente doméstico para limpiar los filtros HEPA Limpie el exterior de la unidad con un paño seco una vez al mes NUNCA use agua cera lustrador ni ninguna otra solución química para limpiar la parte...

Отзывы: