1. 

POWER:

 Turn the air conditioner on or off.

2. 

Cool:

 Press the COOL button to enter COOL mode.

3. 

 and  :

 Use these buttons on the control panel and remote to increase or decrease the Set 

Temperature or Timer. Temperature range: 61°F-88°F or 16°C-31°C.

4. 

Sleep:

 Press the SLEEP button, all of the display lights will turn off after a while with only the Sleep 

light on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed 

to make the room comfortable while you sleep. The set temperature will automatically rise every 

30-60 minutes and at most change six times until the set temperature reaches 81°F or 82°F.

5. 

TIMER:

 

  Timer Off:

 When the unit is on, press TIMER button to set timer off. Set the timer by pressing the 

button “ 

 

” or “ 

 

” until your desired time is reached. Press TIMER button again to confirm.

  Timer On:

 When the unit is off, press TIMER button once and set the temperature by pressing “ 

 

”  

or “ 

 

 

. Press TIMER button a second time, set the timer by pressing the button “ 

 

” or  “ 

 

 

Press TIMER button a third time to confirm the setting.

 

NOTE:

 It can be set to automatically turn off or on in 0.5-24 hours. Each press of the “ 

 

” “ 

 

”  

buttons will increase or decrease the timer in 0.5 hour increment below 10 hours and 1 hour 

increment for 10 hours or above. The SET light will turn on while setting. To cancel the set function, 

press the TIMER button again.

6. 

Auto Mode:

 In AUTO mode the unit automatically chooses the mode of operation (COOL, DRY or 

FAN). In this mode the temperature will be set automatically according to the room temperature 

(tested by the temperature sensor which is incorporated in the indoor unit.).

7. 

Fan Speed:

 Press the FAN SPEED button for various fan speed options. You can choose Hi, Med, Lo 

or auto speed in COOL mode and choose Hi, Med, Lo in FAN mode.

8. 

Display:

 Press the DISPLAY button to switch off/on all lights or LED display.

9. 

ECO:

 When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off once 

the room is cooled to the set temperature. The unit will turn back on when the room temperature 

rises above the set temperature. Before the compressor starts, the fan motor will turn on and off 

repeatedly to provide comfortable feeling and save energy.

10. 

Fan Only:

 Press the FAN ONLY button if you need Fan Only mode.

Содержание HME030341N

Страница 1: ...Window AC HME030341N HME030342N Thank you for selecting our quality appliance Please be sure to read this user manual carefully before using Any question please contact the professional service for help ...

Страница 2: ... in In the event this product malfunctions or customer believes it is defective the customer should contact Customer Service and retain the defective product pending further instructions Defective product should be clearly marked or stored where it cannot be used again by mistake Failure to retain the product may impede hOme s ability to correct any legitimate problem and may limit the extent to w...

Страница 3: ...tant Satety Instructions Electrical Requirements Operating Instructions Cleaning and Maintenance Troubleshooting Warranty Manufacturing Info Warning Contact Us 6 7 8 9 19 20 21 22 22 22 22 TABLE OF CONTENTS ...

Страница 4: ......

Страница 5: ... appliance Congratulations Don t forget to register your product at homelabs com reg for updates coupons and other relevant information Although greatly appreciated product registration is not required to activate any warranty ...

Страница 6: ...adapter Do not use an extension cord Unplug the air conditioner before servicing Use two or more people to move and install the air conditioner This is a safety alert symbol This symbol alerts you to potential hazards that can harm you or others or even cause death All safety messages will directly follow the safety alert symbol and or the words DANGER or WARNING Failure to immediately follow thes...

Страница 7: ...nded This air conditioner is equipped with a 3 prong power supply cord with a grounded plug To minimize the possibility of electrical shock the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances If a 3 prong outlet is not available it is the customer s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrici...

Страница 8: ...d trip and cut all power to the air conditioner on some units a green light may turn off 4 Press the RESET button for use You will hear a click and the unit is ready for use NOTES The RESET button must be engaged for proper use The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch ...

Страница 9: ... sponge 1 Lock Frame 2 Filler Panels With Left Right remark on the front face 2 Sash Lock Two holes 1 Window Sash Seal Sponge 1 3 8 Screws 4 1 2 Screws 3 3 4 Screws 4 Foam Top Window Gasket Thin sponge for backup using 1 Insulation strip Sponge Only for E star model 2 Battery 2 Operating Instructions ...

Страница 10: ...be installed without the accordion panels to fit in a narrow window opening See the window dimensions 3 The Lower Sash the lower part of the window that moves up and down must allow for 14 5 of vertical clearance when open 4 All supporting parts must be secured to firm wood masonry or metal 5 The electrical outlet must be within reach of the power cord NOTE Save the product packaging and installat...

Страница 11: ...t the accordion panels to fit in a narrow window opening See the window dimensions 3 The Lower Sash the lower part of the window that moves up and down must allow for 16 of vertical clearance when open 4 All supporting parts must be secured to firm wood masonry or metal 5 The electrical outlet must be within reach of the power cord Operating Instructions NOTE Save the product packaging and install...

Страница 12: ...A 3 Align the hole in the top rail with those in the top of the unit as shown in FIG B 4 Secure the top rail to the unit with the 3 8 screws as shown in FIG C CAUTION When handling the unit be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils MOUNTING HARDWARE 3 4 Screws 1 2 Screws Lock Frame Sash Lock 4 3 2 1 TOOLS NEEDED Phillips Screw Driver Drill If...

Страница 13: ...the rear must be maintained 1 Use the 4 3 8 screws to fasten the top mounting rail to the unit Top Mounting Rail 4 3 8 Screws 2 Fasten the accordion styled window panel expander pieces to the unit They are marked Right and Left Pull the leading edge to its maximum width Then slide the panel expanders into the grooved notches slide downward on the sides of the unit and make sure they are inserted i...

Страница 14: ... drill a pilot hole in the window frame to fasten these screws to the window sash Attach the lock frame between the panel extender and the window sill and fasten them together with the included locking screw Repeat for each side 2 3 4 Screws 3 1 2 Screws 5 Attach the sash lock between the top of the sliding window and window frame using 1 of the included screws to secure the window closed Sash Loc...

Страница 15: ...ard to drain any condensed water in the base of unit Be careful not to spill any remaining water while lifting unit from window Store parts WITH air conditioner AIR CONDITIONER USE Operating your air conditioner properly helps you to obtain the best possible results This section explains proper air conditioner operation IMPORTANT If you turn off the air conditioner wait at least 3 minutes before t...

Страница 16: ...ve moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during rainy days or days of high humidity Water may overflow and drip from the outside part of the unit The fan may run even when the compressor is not on 1 Digital Display When the timer is not in use the operation mode and the set temperature will be disp...

Страница 17: ...time to confirm the setting Note It can be set to automatically turn off or on in 0 5 24 hours Each press of the buttons will increase or decrease the timer in 0 5 hour increment below 10 hours and 1 hour increment for 10 hours or above The SET light will turn on while setting To cancel the Timer function press the TIMER button again 6 Eco Button When the unit is in ECO mode the light will turn on...

Страница 18: ...18 Operating Instructions REMOTE CONTROL Battery Size AAA NOTE Do not mix old and new batteries or different types of AAA batteries ...

Страница 19: ... time to confirm the setting NOTE It can be set to automatically turn off or on in 0 5 24 hours Each press of the buttons will increase or decrease the timer in 0 5 hour increment below 10 hours and 1 hour increment for 10 hours or above The SET light will turn on while setting To cancel the set function press the TIMER button again 6 Auto Mode In AUTO mode the unit automatically chooses the mode ...

Страница 20: ...To minimize wear and tear on the air conditioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping CABINET CLEANING To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth or...

Страница 21: ...The air filter is dirty Clean the filter See the Cleaning and Care Section of the manual The room may be too warm Please allow time for the room to cool down after turning on the air conditioner Cold air is escaping Check for open furnace registers and cold air returns The cooling coils are frozen See Air Conditioner is freezing up below The Air Conditioner is freezing up Ice blocks the air flow a...

Страница 22: ...mmend that you register your product on our website homelabs com reg Although greatly appreciated the product registration is not required to activate any warranty and product registration does not eliminate the need for the original proof of purchase The warranty becomes void if attempts at repair are made by non authorized third parties and or if spare parts other than those provided by hOme are...

Страница 23: ......

Страница 24: ... 2016 hOme Technologies LLC 37 East 18 Street 7th Floor New York NY 10003 For household Use Only 1 800 898 3002 help homelabs com homelabs com help All rights reserved hOme Printed in China ...

Отзывы: