LCDI POWER CORD AND PLUG

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that 

is required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. 

If the cord is damaged and leakage occurs, power will be disconnected from the unit.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test 

the plug:

1.  Plug power cord into a grounded 3 prong outlet.
2.  Press RESET (on some units a green light will turn on).
3.  Press the TEST Button, The circuit should trip and cut all power to the air conditioner (on some 

units a green light may turn off).

4.  Press the RESET button for use. You will hear a click and the unit is ready for use.

NOTES:

•  The RESET button must be engaged for proper use.
•  The power supply cord must be replaced if it fails to trip when the 

TEST button is pressed and the unit fails to reset.

•  Do not use the power supply cord as an ON/OFF switch. The power 

supply cord is designed as a protection device.

•  A damaged power supply cord must be replaced with a new power 

supply cord.

•  The power supply cord contains new user serviceable parts. Opening 

the tamper-resistant case voids all warranty and performance claims.

NOTES:

The power cord and plug may differ from the one shown above.

Electrical Requirements

A. Reset button

B. Test button

The electrical ratings for your air conditioner are listed on the model and serial number label located on 

the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type 

of plug on the power supply cord.

Wiring Requirements

Power Supply Cord

•  115vol (103min - 127max)
• 

(8K) 0-8 amps

 

(10K-12K) 0-12 amps

• 

(8K) 10-amp time-delay fuse or circuit breaker

 

(10K-12K) 15-amp time-delay fuse or circuit breaker

•  Use on single outlet circuit only

Recommended Ground Method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 

3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord 

must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. 

If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong 

outlet installed by a qualified electrician.

It is the customer’s responsibility:

• 

To contact a qualified electrician

• 

To assure that the electrical installation is adequate and in conformance with the National 

Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from:

• 

National Fire Protection Association

• 

One Batterymarch Park

• 

Quincy, Massachusetts 02269

Electrical Requirements

Содержание HME030340N

Страница 1: ...Window AC HME030340N Thank you for selecting our quality appliance Please be sure to read this user manual carefully before using Any question please contact the professional service for help ...

Страница 2: ...hroughout their journey Please leave it standing upright and outside the box for 24 HOURS before plugging it in In the event this product malfunctions or customer believes it is defective the customer should contact Customer Service and retain the defective product pending further instructions Defective product should be clearly marked or stored where it cannot be used again by mistake Failure to ...

Страница 3: ... appliance Congratulations Don t forget to register your product at homelabs com reg for updates coupons and other relevant information Although greatly appreciated product registration is not required to activate any warranty ...

Страница 4: ...ations and also national wiring regulation It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner Be aware that refrigerants may not contain an odor This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or supervision or instruction concerning use of the appliance by a person r...

Страница 5: ... ASSEMBLY INSTRUCTIONS CONT Please note that 1 The installation site should be in a well ventilated condition 2 The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding smoking drying oven or any other heat source higher than 548 which easily produces open fire 3 When installing an air conditioner it is necessary to take appropriate...

Страница 6: ...er from the one shown above Electrical Requirements A Reset button B Test button The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit when facing the front Specific electrical requirements are listed in the chart below Follow the requirements below for the type of plug on the power supply cord Wiring Requirements...

Страница 7: ...ical clearance when open 4 All supporting parts must be secured to firm wood masonry or metal 5 The electrical outlet must be within reach of the power cord NOTE Save the product packaging and installation instructions for future reference Store the air conditioner in the product box when not in use for an extended period of time PACKING LIST IMAGE PART QUANTITY Window Air Conditioner 1 Remote Con...

Страница 8: ...ION When handling the unit be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils NOTE For safety reasons all 4 screws must be used to attach the top rail INSTALLATION ASSEMBLY INSTRUCTIONS USED FOR 10K 12K Some assembly is required for your new air conditioner Please read and follow these instructions carefully 1 This air conditioner is designed to be in...

Страница 9: ...window closed Sash Lock 3 4 Screw Window sill Lock frame Filler panel Sash Seal 6 To prevent outside air from entering the room insert the foam top window gasket cut to the width of the window 7 Plug the unit into the electrical outlet as specified above in the electrical requirements Move the control to the COOL mode Operating Instructions HOW TO INSTALL NOTE Top Rail and Sliding Panels at each s...

Страница 10: ...DOW Add wood as shown in figure below or remove storm window before air conditioner is installed FIG 14 If storm window frame must remain make sure the drain holes or slots are not caulked or painted shut Accumulated rain water or condensation must be drained out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock Remove screw...

Страница 11: ...n off or on in 0 5 24 hours Each press of the buttons will increase or decrease the timer in 0 5 hour increment below 10 hours and 1 hour increment for 10 hours or above The SET light will turn on while setting To cancel the Timer function press the TIMER button again 6 Eco Button When the unit is in ECO mode the light will turn on In ECO mode the unit will turn off once the room is cooled to the ...

Страница 12: ...ECO mode the unit will turn off once the room is cooled to the set temperature The unit will turn back on when the room temperature rises above the set temperature Before the compressor starts the fan motor will turn on and off repeatedly to provide comfortable feeling and save energy 10 FAN ONLY Press the FAN ONLY button if you need Fan Only mode Cleaning and Maintenance Clean your air conditione...

Страница 13: ...ce hOme offers a limited two year warranty warranty period on all of our products purchased new and unused from hOme Technologies LLC or an authorized reseller with an original proof of purchase and where a defect has arisen wholly or substantially as a result of faulty manufacture parts or workmanship during the warranty period The warranty does not apply where damage is caused by other factors i...

Страница 14: ......

Страница 15: ... 2016 hOme Technologies LLC 37 East 18 Street 7th Floor New York NY 10003 For household Use Only 1 800 898 3002 help homelabs com homelabs com help All rights reserved hOme Printed in China ...

Отзывы: