Home HME030340N Скачать руководство пользователя страница 11

20

21

Operating Instructions

4. 

Mode Button:

 Press the mode button to cycle through the various modes: Cool, Dry, Fan and Auto.

 

Cool Mode:

 The cooling function allows the air conditioner to cool the room and at the same 

time reduces air humidity. Press the MODE button to activate the cooling function. To optimize 

the function of the air conditioner, adjust the temperature and the speed by pressing the button 

indicated.

 

Dry Mode:

 This function reduces the humidity of the air to make the room more comfortable. Press 

the MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air 

fan is activated. Dry mode only can be controlled on control panel.

 

Fan Mode:

 The conditioner works in only ventilation. Press MODE button to set the FAN mode. With 

pressing SPEED button the speed changes in the following sequence: Hi, Med and Lo in FAN mode. 

The remote control also stories the speed that was set in the previous mode of operation.

 

Auto Mode:

 In AUTO mode the unit automatically chooses the mode of operation (COOL, DRY or 

FAN). In this mode the temperature will be set according to the room temperature (measured by the 

temperature sensor which is incorporated in the indoor unit.).

5. 

Timer Button:

 Use these buttons on the control panel and remote to set the Timer.

  Timer Off:

 The timed stop is programmed by pressing TIMER button. Set the timer by pressing the 

button “ ” or “

” until your desired time is reached. Then press TIMER button again to confirm.

  Timer On:

 When the unit is off, press TIMER button once. Set the temperature by pressing the 

button “ ” or “

”. Press TIMER button a second time, set the time by pressing the button  

“ ” or “

”. Press TIMER button a third time to confirm the setting.

 Note:

 It can be set to automatically turn off or on in 0.5-24 hours. Each press of the “ ” “

”  

buttons will increase or decrease the timer in 0.5 hour increment below 10 hours and 1 hour 

increment for 10 hours or above. The SET light will turn on while setting.

  To cancel the Timer function, press the TIMER button again.

6. 

Eco Button:

 When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off 

once the room is cooled to the set temperature. The fan will also be off at this point.  The unit will 

turn back on when the room temperature rises above the set temperature. Before the compressor 

starts, the fan motor will turn on and off repeatedly to provide comfortable feeling and save energy.

7. 

Sleep Button:

 Press the SLEEP button, all of the display lights will turn off after a while, leaving only 

the Sleep light on. In SLEEP mode, the air conditioner will automatically adjust the temperature and 

fan speed to make the room more comfortable during night. The set temperature will automatically 

raise every 30-60 minutes, and at most change six times until the set temperature is 81

°F

 or 82

°F. 

Set fan speed to low before turning on the SLEEP mode.

8. 

Speed Button:

 Press the SPEED button for various fan speed options. You can choose Hi, Med, Lo or 

Auto speed in COOL mode and choose Hi, Med, Lo in FAN mode.

9. 

Filter Button:

 When the Filter Check light is off, it is not necessary to press the Filter Check button. 

When the Filter Check light is on, turn off the light by pressing the Filter Check button. After the 

working time of fan motor reaches 500 total hours, the Filter Check light will turn on to remind the 

user to clean the filter.

10. 

Directional Louvers:

 To direct the airflow, use the horizontal wheel to control the horizontal 

direction, and the air deflectors to control the vertical direction.

Operating Instructions

REMOTE CONTROL

Battery Size:

 AAA

NOTE: 

Do not mix old and new 

batteries or different types of 

AAA batteries.

USING YOUR AIR CONDITIONER (CONT.)

Содержание HME030340N

Страница 1: ...Window AC HME030340N Thank you for selecting our quality appliance Please be sure to read this user manual carefully before using Any question please contact the professional service for help ...

Страница 2: ...hroughout their journey Please leave it standing upright and outside the box for 24 HOURS before plugging it in In the event this product malfunctions or customer believes it is defective the customer should contact Customer Service and retain the defective product pending further instructions Defective product should be clearly marked or stored where it cannot be used again by mistake Failure to ...

Страница 3: ... appliance Congratulations Don t forget to register your product at homelabs com reg for updates coupons and other relevant information Although greatly appreciated product registration is not required to activate any warranty ...

Страница 4: ...ations and also national wiring regulation It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner Be aware that refrigerants may not contain an odor This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or supervision or instruction concerning use of the appliance by a person r...

Страница 5: ... ASSEMBLY INSTRUCTIONS CONT Please note that 1 The installation site should be in a well ventilated condition 2 The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding smoking drying oven or any other heat source higher than 548 which easily produces open fire 3 When installing an air conditioner it is necessary to take appropriate...

Страница 6: ...er from the one shown above Electrical Requirements A Reset button B Test button The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit when facing the front Specific electrical requirements are listed in the chart below Follow the requirements below for the type of plug on the power supply cord Wiring Requirements...

Страница 7: ...ical clearance when open 4 All supporting parts must be secured to firm wood masonry or metal 5 The electrical outlet must be within reach of the power cord NOTE Save the product packaging and installation instructions for future reference Store the air conditioner in the product box when not in use for an extended period of time PACKING LIST IMAGE PART QUANTITY Window Air Conditioner 1 Remote Con...

Страница 8: ...ION When handling the unit be careful to avoid cuts from the sharp metal edges and aluminum fins on the front and rear coils NOTE For safety reasons all 4 screws must be used to attach the top rail INSTALLATION ASSEMBLY INSTRUCTIONS USED FOR 10K 12K Some assembly is required for your new air conditioner Please read and follow these instructions carefully 1 This air conditioner is designed to be in...

Страница 9: ...window closed Sash Lock 3 4 Screw Window sill Lock frame Filler panel Sash Seal 6 To prevent outside air from entering the room insert the foam top window gasket cut to the width of the window 7 Plug the unit into the electrical outlet as specified above in the electrical requirements Move the control to the COOL mode Operating Instructions HOW TO INSTALL NOTE Top Rail and Sliding Panels at each s...

Страница 10: ...DOW Add wood as shown in figure below or remove storm window before air conditioner is installed FIG 14 If storm window frame must remain make sure the drain holes or slots are not caulked or painted shut Accumulated rain water or condensation must be drained out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock Remove screw...

Страница 11: ...n off or on in 0 5 24 hours Each press of the buttons will increase or decrease the timer in 0 5 hour increment below 10 hours and 1 hour increment for 10 hours or above The SET light will turn on while setting To cancel the Timer function press the TIMER button again 6 Eco Button When the unit is in ECO mode the light will turn on In ECO mode the unit will turn off once the room is cooled to the ...

Страница 12: ...ECO mode the unit will turn off once the room is cooled to the set temperature The unit will turn back on when the room temperature rises above the set temperature Before the compressor starts the fan motor will turn on and off repeatedly to provide comfortable feeling and save energy 10 FAN ONLY Press the FAN ONLY button if you need Fan Only mode Cleaning and Maintenance Clean your air conditione...

Страница 13: ...ce hOme offers a limited two year warranty warranty period on all of our products purchased new and unused from hOme Technologies LLC or an authorized reseller with an original proof of purchase and where a defect has arisen wholly or substantially as a result of faulty manufacture parts or workmanship during the warranty period The warranty does not apply where damage is caused by other factors i...

Страница 14: ......

Страница 15: ... 2016 hOme Technologies LLC 37 East 18 Street 7th Floor New York NY 10003 For household Use Only 1 800 898 3002 help homelabs com homelabs com help All rights reserved hOme Printed in China ...

Отзывы: