Page 7
Installation
Excessive Weight
Require two or more person to move and
install this range hood. Spinal or other bodi-
ly injuries could occur if it is not followed.
INSTALL THE HOOD
Due to excessive weight, two or more person is recommended for this step.
NOTE: the hood has to be installed, inside the cabinet, at
minimum 1-1/2” from the rear wall cabinet and at 2” from the front wall cabinet.
The internal height of cabinet has to be minimum 28”.
The hood should be mounted centered over the cook top burners.
Remove the decorative panel from the range hood.
1.
Cut a hole in the bottom of the cabinet, using the dimensions shown in the table below (ref. to Fig. A).
2.
Insert the hood in the cabinet and secure with the (4) mounting screws from the inner side of the range hood
3.
(Fig. B).
Note: Wood blocking might need to be built if it’s not available in order to secure the mounting
screws.
In the Non-Ducted Recirculation Configuration, install the Non-ducted recirculation Filter before replacing
4.
the grid (see section “Non-ducted recirculation filter installation”).
Replace the decorative panel.
5.
Wood Blocking
Fig. B
Fig. A
Cut a hole in the bottom of the
cabinet
X
Y
Model
X
Y
E50-20
19 1/2”
11 1/4”
E50-28
25 1/2”
11 1/4”
E70-27/S27
26 1/2”
10 3/4”
E70-30/S30
28 1/2”
10 3/4”