2
1
Operation – Natural Gas Conversion (continued)
4
Disconnecting the propane hose
5
Connecting to the natural gas supply
piping system
□
Connect the natural gas hose with the gas valve by screwing
clockwise tightly.
□
Plug the natural gas fixture into the natural gas supply piping
system.
6
□
Stick and cover the conversion label onto the propane rating
plate.
water column
Model Number: FG-BTB5PCFC-FP
Serial Number:
DANGER
Minimum clearance from combustible constructions: Sides:24in. 610mm. Top:72in. 1829mm.
FOR OUTDOOR USE ONLY.
If stored indoors, detach and leave cylinder outdoors. Do not connect to a remote
gas supply. It is shipped with LP gas orifice. You can find the orifices on the package with LP manual. Please
follow the instructions package with the orifices for gas conversion.
1.
Push in gas control knob slightly and turn to “OFF”.
2.
Turn gas control knob to “ON/MIN”.
3.
Push in gas control knob all the way and hold. Continue to press the ignition
button for 15 seconds.
4.
If the burner does not light in 15 seconds, release the knob and it will pop
back out. Wait 5 minutes before attempting to light the burner again, repeat step 1
to 3.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
1.
Push in gas control knob slightly and turn to “OFF”.
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or home.
Design Certified by CSA Group
ANS Z21.97/CSA 2.41-2014
Outdoor Decorative Gas Appliances
WARNING: Improper installation, adjustment alteration, service or maintenance can cause injury
or property damage. Read the installation, operating, and maintenance instructions thoroughly
before installing or servicing this equipment.
WARNING: Do not store or use
gasoline, or other flammable
vapors and liquids, in the vicinity
of this or any other appliance.
An LP-cylinder not connected for
use shall not be stored in the
vicinity of this or any other
appliance.
Manifold Pressure : 11 inches
Distributed by Foremost Groups, Inc.
906 Murray Road, East Hanover, NJ 07936, U.S.A.
ϒ⁄
The instruction manual contains important information necessary for the proper assembly and safe use of the appliance.
ϒ⁄
Read and follow all warnings and instructions before assembling and using the appliance.
ϒ⁄
Follow all warnings and instructions when using the appliance.
ϒ⁄
If instructionsor parts are missing, contact Foremost Groups Customer Relations Department toll free number at
1-855-390-5474 (USA) or 001-855-286-4931 (Int) between the hours of 8:30 am and 5:00 pm EST, Monday through
Friday or fax your request to (973) 428-8026 or email us at [email protected]
S
E
D
GN
R
E
C
T I F
I
I E
D
R
CAUTION
: This appliance has been converted to use natural gas.
Propane orifice dia2.09mm, natural gas orifice dia4.18mm.
Rated Heat Input : 50,000 BTU/hr
Type of Gas : Natural gas
Max Gas Supply Pressure : 7 inches water column (1.74kPa)
Min. Gas Supply Pressure : 5 inches water column (1.24kPa)
Applying the conversion label to the
propane rating plate
gas valve
natural gas hose
natural gas fixture
natural gas hose
natural gas supply piping system
conversion label