Operation
□
Your DC brushless motor is equipped with an automatically
learned type wall control. Restore power to ceiling fan and
test the wall control as below for proper operation.
□
Install a 12V MN21/A23 battery (OO) (included) into the wall
control (L). To prevent damage to the wall control (L), remove
the battery if not used for long periods.
WALL SWITCH OPERATING INSTRUCTIONS
WALL SWITCH OPERATING INSTRUCTIONS
Remote Control Button Definitions
Remote Control Button Definitions
These six buttons are used to set the fan speed as follows:
1 = low
2 = medium low
3 = medium
4 = medium high
5 = high
6 = extra high
button: Turns the fan off.
button: Controls fan direction.
button: Controls light. Switch the “D” and “ON” dip switch on
the transmitter to set the light to either the “ON/OFF” or
“Dimmable” condition.
ON - OFF Slide button: This button turns the power on and off to
the fan and light.
Setting the Remote Control
Setting the Remote Control
Follow the below steps to set the remote control:
The auto learning function will only mandate within 60 seconds
when turning the fan’s AC power ON.
□
Select desired frequency from the back of transmitter.
□
Remove the panel from the wall control; press the “SET”
button, and hold the “SET” button for over 5 seconds. Once
the receiver has detected the frequency, the light will flash
twice, and the fan will automatically begin to operate and
start to rotate in the counterclockwise direction and on the
highest RPM for 3 minutes. When counterclockwise rotation
has finished, the fan will automatically reverse to clockwise
direction again to the highest RPM for 3 minutes. Fan will shut
off when the self calibration test has finished. The total self
calibration test will last about 6 minutes.
L
OO
NOTE:
If the self calibration test failed, turn the AC
power off; restore power and process the self calibra-
tion test again.
NOTE:
The learning frequency function and self
calibration test will continue to retain the last set
frequency and calibration set even when the AC power
is shut off. If the frequency is changed the self calibra-
tion test will occur again.
NOTE:
During self calibration test, the remote is
non-fuctional.
“D” and “ON” dip switch:
□
The “ON” selection is the light dimmable selection and is to
be used with all bulbs except for CFL bulbs. The “D” selection
is the light ON only (no dimming function) and is to be used
with CFL bulbs as CFL bulbs in most cases cannot be used
with dimming controllers.
This receiver provides the following protective function:
□
Lock Rotor Position: The DC motor has a built-in safety against
a stalled or locked rotor condition (stalled blade rotation). If
there is an obstruction or fault with the motor, the current
monitoring function will automatically turn power off to the
motor after 30 seconds. Remove the obstruction and turn the
AC power off. Restore power and re-start fan motor.
□
Over 80W protection: When the receiver detects motor power
consumption which is greater than 80W, the receiver power
will be stopped and operation will immediately discontinue.
Wait for 5 seconds and then turn the receiver power back on.
17
HOMEDEPOT.COM/HOMEDECORATORS
Please contact 1-800-986-3460 for further assistance.