Lock Type
The Lock Type specifies the type of door lock that is connected to the selected Access Control Reader. The Lock Type can be either
be configured for a "Fail Secure" device (door is locked when power fails) or "Fail Safe" mode (door is unlocked when power fails).
READER 1 LOCK TYPE: 0
0=SECURE 1=SAFE
Select 0 (Secure) when connecting a “Fail Secure” lock or select 1 (Safe) when connecting a “Fail Safe” lock, followed by the ' # '
key. The default setting is “Fail Secure”.
Reader Beeper
The Reader Beeper setting is used to enable and disable the beeper in the selected Access Control Reader.
When the beeper is set to “Yes”, every time a valid Access Control Card or Key Tag is presented at the reader, the beeper will produce
a single short beep. If the reader is used to arm or disarm the security system, the beeper will produce a single long beep.
When the beeper is set to “No”, the reader will not beep when a valid Access Control Card or Key Tag is presented at the reader or
when the reader is used to arm or disarm the security system.
READER 1 BEEPER: 1
0=NO 1=YES
To disable the beeper, select 0 (No) followed by the ' # ' key. To enable the beeper, select 1 (Yes) followed by the ' # ' key. The
default setting for the beeper is enabled (Yes).
Reader Arm/Disarm
The Reader Arm/Disarm setting is used to enable or disable the reader for arming and disarming the security system in the respective
area when a valid Access Control Card or Key Tag is presented at the selected Access Control Reader 3 times within 5 seconds of the
previous presentation of the card.
When Arm/Disarm is set to “Yes”, when a valid Access Control Card or Key Tag is presented at the reader 3 times within 5 seconds
of the previous presentation of the card, the Access Control Reader will produce a single long beep and the security system will:
(a)
Arm to the Away mode (in the respective area) if the security system is currently disarmed, OR
(b)
Disarm the security system (in the respective area) if the security system is currently armed in any security mode
When Arm/Disarm is set to “No”, the selected Access Control Reader can not be used to arm or disarm the security system.
READER 1 ARM/DISARM: 1
0=NO 1=YES
To disable arming and disarming from the selected reader, select 0 (No) followed by the ' # ' key. To enable arming and disarming at
the selected reader, select 1 (Yes) followed by the ' # ' key. The default setting for Reader Arm/Disarm is enabled (Yes).