Area Assignment 
 

Each Access Control Reader can be assigned to a specific Area on the controller.  When used for security arming and disarming, the 
security mode of the Area where the Access Control Reader is assigned will be changed. 
 

 

 

 

READER 1 AREA:         1

 

 

 

 

1-8                    

 

 
Enter the Area for the selected Access Control Reader followed by the ' # ' key. 
 
 

Link Assignment 

 
A Link Assignment is used when two Access Control Readers are used to control access to the same door (i.e. one reader on the inside 
and the other on the outside of the restricted door).  This is useful when an Access Control Card or Key Tag is required to enter or exit 
through a restricted door.   
 
Since the door lock is physically connected to a single Access Control Reader, the Link Assignment links the selected Access Control 
Reader with a second Access Control Reader so that when a valid Access Control Card or Key Tag is presented at either Access 
Control Reader, the door is unlocked.  Furthermore, the controller will log which Access Control Reader was used to access the door 
(i.e. whether the user was entering or exiting the door). 
 

 

 

 

READER 1 LINKED TO:    0

 

 

 

 

0-16                   

 

 
Enter the reader number of the Access Control Reader that will be linked to the selected reader, followed by the ' # ' key. 

 
Notes:  
 

 

Only two Access Control Readers can be linked together. 

 

When a valid Access Control Card of Key Tag is presented at either linked Access Control Reader, the 9 LED indicators on both 
linked Access Control Readers will illuminate the color of the current security arming state for that area and will remain 
illuminated while the door is unlocked. 

 
 

Unlock Time 
 

The Unlock Time is the amount of time that the door remains unlocked when a valid Access Control Card or Key Tag is presented at 
the Access Control Reader.  The Unlock Time can be between 1-60 seconds and is individually configured for each reader.  
 

Note:

 When the door is unlocked due to a valid Access Control Card or Key Tag is presented, all 9 LED indicators will illuminate the 

color of the current security arming state for that area and will remain illuminated while the door is unlocked. 

 

 

 

 

READER 1 UNLK TIME:    5

 

 

 

 

1-60 SECONDS           

 

 

Enter the Unlock Time (1-60 seconds) for the selected Access Control Reader, followed by the ' # ' key.  The default time is 5 seconds. 

 

 
Exit Time

 

 
The Exit Time is the amount of time that the door remains unlocked when the “Request to Exit” input is tripped.  An optional device, 
such as a “Request to Exit” button which is mounted on the inside of the restricted door, is used to unlock the door without requiring a 
second Access Control Reader.  The Exit Time can be between 1-60 seconds and is individually configured for each reader. 
 

Note:

 When the door is unlocked due to pressing a “Request to Exit” button, none of the LED indicators will illuminate. 

 

 

 

 

READER 1 EXIT TIME:    5

 

 

 

 

1-60 SECONDS           

 

 

Enter the Exit Time (1-60 seconds) for the selected Access Control Reader, followed by the ' # ' key.  The default time is 5 seconds.

 

Содержание HAI

Страница 1: ...LED indicators illuminate red The security system in the respective area is currently armed LED indicators illuminate green The security system in the respective area is currently disarmed Note The L...

Страница 2: ...t a pathway into the house change the temperature and turn on several zones of a whole home audio system and select their volume and source Access Control Setup When Access Control is part of your sys...

Страница 3: ...l Card or Key Tag has not been swiped 3 times within the first 3 minutes the controller will automatically exit configuration mode Deleting Access Control Cards or Key Tags To delete an Access Control...

Страница 4: ...s Control Card and Key Tag Activity Each Access Control Card or Key Tag that is enrolled in the system can be configured to log activity whenever the card is presented at a reader even if the user was...