Naftový horkovzdušný ohřívač / diesel gas burner HKD15 / HKD30T
14.3.1
START
Plug the heater into a grounded 230V/50 Hz outlet, make sure POWER switch is “Off”.
Start heater by press the ON/OFF switch (key for Type T) to “On” position. Heater will run
on and off automatically according to the required room temperature set.
CAUTION This unit is equipped with a self-detecting unit, which will run 3 seconds before
the ventilator motor rotates. If some minor defects are detected, the units will try 3 cycles
of restart automatically. Each cycle lasts 7 seconds. NOT touch the ON/OFF switch (key for
Type T) during this period.
14.3.2
STOP
TEMPORARY STOP
Press the ON/OFF switch (key for Type T) off.
After 2 minutes of self-cooling, the motor will stop rotating automatically.
CAUTION In cold weather, starting may be improved by holding a finger over the end of
the pressure adjusting screw until the heater starts.
Restart after Temporary Stop. Press the ON/OFF switch (key for Type T) on, the heater will
enter into normal operation again.
SAFETY STOP
Press the ON/OFF switch (key for Type T) off.
After 2 minutes of self-cooling, the motor will stop rotating automatically.
Unplug heater from receptacle of power supply.
IMPORTANT: Never unplug by pulling the power cord. cord
CAUTION: After temporary stop the heater is still electrically alive. NEVER try to move the
heater after temporary!