ASSEMBLY
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
Seite 39
METALLDREHMASCHINE / METAL TURNING LATHE ED 1000N / ED 1000NDIG
13.2.4
Cleaning
Remove the anti-corrosion protection and grease before putting the machine through kerosene
(paraffin) or turpentine of all tours and the transmission. Do not use thinner or other strong
solvents. Lubricate all the bright faces of the machine directly after its cleaning. Do not use heavy
oil or grease for the gearbox.
13.2.5
Installation
Place the lathe on a solid surface. A concrete floor is the best foundation for the machine, if
necessary, use a base. Make sure that you have enough space around the machine to optimally
operate and maintain. Adjust the guides exactly a bed, then tighten the foundation bolts evenly
and finally check the stand
13.3
Power supply
A T T E N T I O N
When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore
: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power
socket!
2.
The connector plug may not be manipulated.
3.
hemainssupplymust be securedwith16A:
4.
If the connector plug doesn’t fit or if it is defect, only qualified electricians may modify or re-
new it!
5.
The grounding wire should be held in green-yellow.
6.
A damaged cable has to be exchanged immediately!
7.
Check, whether the feeding voltage and the Hz comply to the required values of the ma-
chine. A deviation of feeding voltage of ±5% is allowed (e.g.: a machine with working voltage
of 380V can work within a voltage bandwidth of 370 till 400V.
8.
Make surethata possibleextension cordisin good condition andsuitableforthe transmission of
power. Anundersizedcordreducesthe transmission of powerandheats up.
9.
A damagedcable must bereplaced immediately
N O T I C E
Operation is only allowed with safety switch against
stray current (RCD max. stray current of 30mA)
N O T I C E
Useonlypermittedextensioncablewithcross-sectiontheone
in thefollowingtabledeclared.
Voltage
Extension
Cross-section
220 V-240 V
<27 m
1,5 mm
2