Holtkamp Electronics DUO XXL techn.stand 01.2018 4022_01.2018/V05.2020
- 13 -
11 Equipment feature
11.1 DIP switches
The DIP-switches are only accessible after opening the
house!
Certain programmings and releases can be made with the DIP
switches (closer information to that at chapter 15 „
Menu set-
tings
”). The function of the DIP switches 1, 2 and 4 can be alter
-
natively activated via service cards, so the houses does not have
to be opened.
Attention: Only for authorized expert personell!
The device is in dangerous voltage!
1 2 3 4
8 x 10 mm component with 4 little switches
(see chapter 7.2). Condition at delivery: DIP
3 switched on, the rest switch off
DIP switch 1:
Calls up the operator-menu, with delete- and
setting right for statistics, and with settings rights
in all other menus.
DIP switch 2:
Releases the initialization of all settings of all
menus and also of the H-numbers of the chip
cards via service cards Typ 20...22.
This initialization is usually carried out by the de-
vice manufacturer! It only has to be repeated if
the XXL device has been to be moved to ano-
ther
place.
DIP switch 3:
Gives up the possibility to change the values of
the menu with the service cards Typ 43 and Typ
(also jumper 1a). (T4183FREE) This switch is
normally always on. By switching off, you can
lock lost or stolen cards.
DIP switch 4:
Releases the reset on factory data. See identi-
cally
named
chapter!
11.2 Jumper
The jumpers are accessible after opening the house.
Attention: Only for authorized expert personell!
The device is in dangerous voltage!
The jumpers 1a, 1b and 1c are easily accessible at the XXL-Po-
wer PCB.
Therewith can be different functions activated:
3- times pole strip for jumper (see chapter 7.2).
Jumper 1a:
Menu call with password (instead of service cards)
Jumper 1b:
unused
Jumper 1c:
unused
The rarely needed Jumper 2a, 2b and 2c are on the smaller XXL-
main PCB. Therewith you can activate rare functions:
3- times pole strip for jumper
2c 2b 2a
Jumper 2a:
unused
Jumper 2b:
large 5,7”-display (instead of a small 3,5”-Display)
only reconnect when the operating voltage is
switched off.
Jumper 2c:
unused