Rev. 1.60
168
August 20, 2019
Rev. 1.60
169
August 20, 2019
BS66F340/BS66F350/BS66F360/BS66F370
Touch A/D Flash MCU with LED Driver
BS66F340/BS66F350/BS66F360/BS66F370
Touch A/D Flash MCU with LED Driver
• I
2
C Bus Read/Write Signal
The SRW bit in the SIMC1 register defines whether the slave device wishes to read data from the
I
2
C bus or write data to the I
2
C bus. The slave device should examine this bit to determine if it is to
be a transmitter or a receiver. If the SRW flag is "1" then this indicates that the master device wishes
to read data from the I
2
C bus, therefore the slave device must be setup to send data to the I
2
C bus as
a transmitter. If the SRW flag is "0" then this indicates that the master wishes to send data to the I
2
C
bus, therefore the slave device must be setup to read data from the I
2
C bus as a receiver.
• I
2
C Bus Slave Address Acknowledge Signal
After the master has transmitted a calling address, any slave device on the I
2
C bus, whose
own internal address matches the calling address, must generate an acknowledge signal. The
acknowledge signal will inform the master that a slave device has accepted its calling address. If no
acknowledge signal is received by the master then a STOP signal must be transmitted by the master
to end the communication. When the HAAS flag is high, the addresses have matched and the slave
device must check the SRW flag to determine if it is to be a transmitter or a receiver. If the SRW flag
is high, the slave device should be setup to be a transmitter so the HTX bit in the SIMC1 register
should be set to "1". If the SRW flag is low, then the microcontroller slave device should be setup as
a receiver and the HTX bit in the SIMC1 register should be set to "0".
• I
2
C Bus Data and Acknowledge Signal
The transmitted data is 8-bits wide and is transmitted after the slave device has acknowledged
receipt of its slave address. The order of serial bit transmission is the MSB first and the LSB last.
After receipt of 8-bits of data, the receiver must transmit an acknowledge signal, level "0", before
it can receive the next data byte. If the slave transmitter does not receive an acknowledge bit signal
from the master receiver, then the slave transmitter will release the SDA line to allow the master
to send a STOP signal to release the I
2
C Bus. The corresponding data will be stored in the SIMD
register. If setup as a transmitter, the slave device must first write the data to be transmitted into the
SIMD register. If setup as a receiver, the slave device must read the transmitted data from the SIMD
register.
When the slave receiver receives the data byte, it must generate an acknowledge bit, known as
TXAK, on the 9
th
clock. The slave device, which is setup as a transmitter will check the RXAK bit
in the SIMC1 register to determine if it is to send another data byte, if not then it will release the
SDA line and await the receipt of a STOP signal from the master.